Utvärdering av energiprojektering för Hedlunda passivhusförskola: Assessment of the projected energy demand for a passive house preschool at Hedlunda
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2017 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

På Hedlunda i Umeå finns Hedlunda förskola; en byggnad som innehåller förskoleverksamhet, ett storkök och en matsal. Byggnaden uppfördes 2014 och började nyttjas samma år. Byggnaden är projekterad av Sweco för att klara krav gällande allt från specialpedagogik till energi och miljö. Den är även certifierad enligt en internationell passivhusstandard. Syftet med examensarbetet är att granska om förskolan håller de energikrav den projekterats för, samt att jämföra byggnadens projekterade energianvändning med den i praktiken uppmätta. Det sistnämnda gjordes även för att utvärdera precisionen hos den projekterade energianvändningen. Energibehovet ställdes även i proportion till de gränsvärden för energikrav som används av andra energicertifieringar.

Byggnaden simulerades i programmet IDA ICE, och de mätvärden som samlades in bearbetades i Microsoft Excel. Programmet PHPP användes även för att granska om förskolan uppfyllde de internationella passivhuskraven.

Byggnaden klarar varken kravet för årlig energianvändning eller kravet för specifikt primärenergibehov. Båda dessa är krav inom den internationella passivhusstandarden. Det föregående överskrids med 14 %, och det senare med 4 %. Byggnaden klarar energikravet för den svenska passivhuscertifieringen med god marginal.

Värdet på byggnadens specifika energianvändning skilde sig knappt alls mellan projekteringen och det uppmätta värdet. Tittar man dock på enskilda faktorer så skiljer sig de projekterade värdena av el och uppvärmning sig mot de uppmätta med större differenser. Störst differens återfinns i faktorn verksamhetsel som överskattades med 60 % i projekteringen. Byggnadens specifika energianvändning uppgick till ca 43 kWh /m2 år  vilket är lägre kraven de vanligaste energistandardena ställer, vilket innebär att byggnaden är osedvanligt energieffektiv.

Om alla lokaler som fick bygglov i Sverige 2015 hade byggts med samma energiprestanda som denna byggnad så hade det gått åt 392 GWh /år , medan om de istället byggts enligt BBRs standard så hade energiåtgången blivit 1098 GWh /år  (exklusive verksamhetsel). Även om olika lokaler har olika behov och krav så ger det en fingervisning av besparingspotentialen. Syftet med byggnaden var att det skulle bli en förebild för framtida energisnåla projekt, vilket det också blev när Vegaskolan i Vännäs byggdes efter samma koncept. På det hela taget är Hedlunda förskola en byggnad med hög energiprestanda.

Abstract [en]

At Hedlunda in Umeå, there’s a building complex containing a combined preschool, canteen and catering kitchen. It was built in 2014 and the preschool started up the same year. Sweco projected the building to satisfy the requisites required for the international passive house certification. The building was also supposed to meet specific requirements for specialized pedagogy, and requirements for non-toxic building materials in preschools, amongst others. In this master thesis the building’s energy usage was studied to see if the building met the requested requirements, and how close the estimated energy demand was to the actual demand. The purchased energy was also compared to energy requirements used by other certification systems used in Sweden today.

The building meets the international passive house requirement for the annual heating demand, but breaches the requirement for primary energy value by 4 %. The Swedish passive house requirement is met with a significant margin.

The purchased energy per square meter was 43 kWh /m2 year , which differed only marginally from the projected value of 41 kWh /m2 year . It may seem as if it was a very good estimation of the purchased energy, but when the factors are studied individually there are differences among them that go up to 60 %. The purchased energy per square meter was lower than all of the other requirements in other energy certification systems which proves that this is a highly efficient building.

The building was created with the main purpose of serving as a model for energy efficient buildings, and it has served its purpose since Vegaskolan in Vännäs was built within the same concept.

All in all, Hedlunda preschool is a building with a very good energy performance. If all public buildings who gained building permit in 2015 in Sweden had been built with the same energy efficiency as Hedlunda preschool, then the total energy demand would be 392 GWh /year , whereas if they were built as the BBR-standard the corresponding energy demand would be 1098 GWh /year . This is just a rough estimation to give a hint of the amount of energy that can be saved.

Place, publisher, year, edition, pages
2017.
Keyword [en]
passivehouse, criteria, assessment, preschool, energy demand, PHI, BREEAM, IDA ICE
Keyword [sv]
passivhus, Hedlunda, uppföljning, energieffektivisering, ventilation, energianvändning, projektering, BREEAM, kriterier, miljöbyggnad, PHI, PHPP, IDA ICE, energikrav
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:umu:diva-135706OAI: oai:DiVA.org:umu-135706DiVA: diva2:1105287
External cooperation
Sweco Systems
Subject / course
Energiteknik
Educational program
Master of Science Programme in Energy Engineering
Supervisors
Examiners
Available from: 2017-06-05 Created: 2017-06-02 Last updated: 2017-06-05Bibliographically approved

Open Access in DiVA

Utvärdering av energiprojektering för Hedlunda passivhusförskola(1339 kB)14 downloads
File information
File name FULLTEXT01.pdfFile size 1339 kBChecksum SHA-512
091d21312116c2d906c43785fc0bb05aab189d3b40d86668e18e6e9c24f122094b3284ec094d3b47065816895007d7e473748a0a5fe0ecac198850ba45e9fecc
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Risberg, Ylva
By organisation
Department of Applied Physics and Electronics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 14 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 100 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf