Temporarily occupied spacewith metabolic-rate-initiated thermal overshoots: a case study in railwaystations in transition seasons
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. (Building Energy Efficiency)
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. (building energy efficiency)
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 122, s. 184-193Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Temporarily occupied space (TOS) is defined as an air-conditioned space in which most of occupants stay for less than a certain period (e.g., 40 min), such as post offices, supermarkets, bookstores, and banks. The definition mainly emphasizes two aspects: obvious temperature step up/down and short-term exposure periods. Typical TOSs with predominantly temperature-initiated thermal overshoots have been explored in previous studies. Indeed, apart from temperature-initiated thermal overshoots, thermal overshoots can also be initiated by other parameters, such as metabolic rates. In this view, the definition of thermal overshoots was generalized and a case study was conducted at high-speed railway station in China under conditions of transition seasons. The phenomenon of metabolic-rate-initiated thermal overshoots instead of temperature-initiated thermal overshoots was observed and explored, based on objective measurements and subjective questionnaire surveys. The results could optimize the design and operation of air conditioning and mechanical ventilation (ACMV) systems in such TOSs as embodied by railway stations. In addition, the probit analysis method for analyzing neutral temperature ranges instead of neutral temperature points was also discussed.

Ort, förlag, år, upplaga, sidor
Oxford: Pergamon Press, 2017. Vol. 122, s. 184-193
Nyckelord [en]
Thermal comfort, Temporarily occupied space, Transition seasons, Metabolic-rate-initiated overshoot
Nationell ämneskategori
Husbyggnad
Identifikatorer
URN: urn:nbn:se:umu:diva-136368DOI: 10.1016/j.buildenv.2017.06.018ISI: 000407184400017OAI: oai:DiVA.org:umu-136368DiVA, id: diva2:1110581
Tillgänglig från: 2017-06-16 Skapad: 2017-06-16 Senast uppdaterad: 2018-06-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Yang, BinOlofsson, Thomas

Sök vidare i DiVA

Av författaren/redaktören
Yang, BinOlofsson, Thomas
Av organisationen
Institutionen för tillämpad fysik och elektronik
I samma tidskrift
Building and Environment
Husbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 143 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf