Konsekvenser av ett omfattande elavbrott inom den kommunala äldrevården
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Consequences of a large-scale power outage within the municipal elderly care (English)
Abstract [sv]

Under det senaste årtiondena har stora samhällsförändringar skett där teknikutvecklingen har inneburit en omvandling från ett industrisamhälle till ett informationssamhälle. I dagens samhälle innefattar nästan alla delsystem komponenter som är beroende av elektricitet. Ökat elberoende innebär sårbarheter för hela samhället men extra sårbart är vårdkedjan. Sveriges sjukhus har robusta system för att klara längre strömavbrott, men en delsektor som inte belysts i samma utsträckning är den kommunala äldrevården.

Detta examensarbete kommer att belysa det kommunala äldreboendens situation under ett långvarigt och omfattande elavbrott under kritiska väderförhållanden. Arbetet undersöker vilka konsekvenser som kan uppstå för ett äldreboende till följd av ett längre elavbrott och vilken förmåga som finns för att hantera en sådan situation vilket ofta innebär någon form av reservkraft.

Arbetet bestod av att kartlägga effektbehovet för en referensbyggnad under kritiska väderförhållanden. Vidare undersöktes nerkylningstiden för byggnaden under en kall vinterperiod vid avbrott i värmetillförsel samt vilken inomhustemperatur som byggnaden skulle uppnå under en varm sommarperiod när inget kylsystem finns att tillgå. Arbetet utfördes med hjälp av simuleringsprogrammet IDA Indoor Climate and Energy samt handberäkningar. Utöver detta undersöktes även konsekvenserna av ett strömavbrott för äldreboenden, vilken förmåga som finns för att hantera detta samt åtgärder som kan införas.

Resultatet av arbetet visar att elberoendet är synnerligen stor och konsekvenserna av ett omfattande längre strömavbrott kan bli mycket stora. Viktiga samhällsfunktioner kan komma att påverkas vilket försvårar situationen på äldreboenden. Inomhustemperaturen sjunker snabbt utan värmesystem under en kall vinterperiod och en varm sommarperiod utan kylsystem skulle innebära stora påfrestningar på äldreboenden. Förmågan att hantera varierar i kommunen och i vissa delar finns inga större resurser i form av reservkraft. Resultatet visar också att det krävs ganska stora reservkraftaggregat för att möta effektbehovet som förbrukar stora mängder bränsle vilket ställe stora krav på en väl fungerande bränsleförsörjning.

Abstract [en]

During the last couple of decades the society has gone through a change where advancement in technology development have meant a transformations from at industrial society to an information society. In today’s society, almost everything contains components which depends on electricity to function. An increasing dependence on electricity makes the society vulnerable and especially the healthcare chain. The Swedish hospitals have capacity to handle longer power breaks, but a subsector which have not been investigated in the same extent is the municipal retirement homes.

 

This thesis will look into the municipal retirement homes situation during a long and large-scale power outage with critical weather conditions. The thesis will analyze the consequences that might emerge due to a power outage and to what extent there is capacity to manage a situation like this which often mean some sort of emergency power.

 

The work consisted of calculating the power requirement for a reference building during critical weather conditions. Furthermore, a simulation was done to investigate the time it took for the building to cool down during a cold winter period with the absent of a heating system and also what the indoor temperature would be in the building during a warm summer period with no access to a cooling system. The work was done with the simulation program IDA Indoor Climate and Energy and hand calculations. In addition, the consequences of a power break for retirement homes was analyzed, what capacity there is to handle this and measures that can be implemented.

 

The result of the work shows that the dependence of electricity is rather large and the consequences of a large-scale power outage can result in big impact on the retirement homes. Important functions in the society might be affected which will make the situation in the retirement homes even worse. The temperature inside the building decreases rapidly without heating systems during a cooled winter period and a hot summer period without a cooling system would mean great stresses on the retirement homes. The ability to manage a large power break varies in the municipality and in some parts there is no resources in the form of emergency power. The result also shows that it requires quite big emergency power generators to meet the power requirement. These generators consume large amount of fuel and it is therefore important to have a well-functioning fuel supply plan.   

Place, publisher, year, edition, pages
2017. , 41 p.
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:umu:diva-137474OAI: oai:DiVA.org:umu-137474DiVA: diva2:1119260
External cooperation
Totalförsvarets forskningsinstitut
Subject / course
Energiteknik
Educational program
Bachelor of Science Programme in Energy Engineering
Supervisors
Examiners
Available from: 2017-07-05 Created: 2017-07-03 Last updated: 2017-07-04Bibliographically approved

Open Access in DiVA

No full text

By organisation
Department of Applied Physics and Electronics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

Total: 1 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf