An experimental study on a novel radiant-convective heating system based on air source heat pump
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics. (Building Energy Efficiency)
Show others and affiliations
2018 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 158, p. 812-821Article in journal (Refereed) Published
Abstract [en]

Air source heat pump (ASHP) has been widely applied to many parts of the world due to its simple structure and low initial cost. To save energy consumed for spacing heating and enhance the indoor thermal environment, improving the performances of ASHP has become one of the research focus in the relevant field. Currently, the most conventional heating terminal of ASHP system for spacing heating is finned tube heat exchanger coupled with air fan, which may cause strong draught sensation and dry eye problem and make users feel uncomfortable during convective heating. On the other hand, radiant heating is attracting more and more attention due to its comfortable indoor thermal environment. In this paper, a novel radiant-convective heating terminal was presented and coupled into an ASHP system. Both the operating characteristics and heating performances of the novel system were experimentally investigated. The experimental results showed that the novel system took about 28 min to enter a steady operating stage, during which the radiant panel surface temperature and outlet air temperature for the novel heating terminal, and COP of the novel system were 40.9 degrees C, 32.1 degrees C, and 3.11, respectively, under a standard heating condition. In addition, all parameters mentioned above saw a linear increase when the outdoor air temperature increased from -4.0 to 10.0 degrees C, and their respective rising rates were 0.41 degrees C, 0.28 degrees C and 0.04 per increased outdoor air temperature. Furthermore, the experimental results also demonstrated that adjusting the indoor air flow rate could effectively allocate the amount of heat generated by different heat transfer modes, which may have significant effects on the indoor thermal environment.

Place, publisher, year, edition, pages
2018. Vol. 158, p. 812-821
Keywords [en]
Experimental study, Radiant heating, Convective heating, Air source heat pump
National Category
Civil Engineering Building Technologies
Identifiers
URN: urn:nbn:se:umu:diva-141055DOI: 10.1016/j.enbuild.2017.10.065ISI: 000423636600069OAI: oai:DiVA.org:umu-141055DiVA, id: diva2:1151598
Available from: 2017-10-23 Created: 2017-10-23 Last updated: 2018-06-09Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records BETA

Yang, Bin

Search in DiVA

By author/editor
Yang, Bin
By organisation
Department of Applied Physics and Electronics
In the same journal
Energy and Buildings
Civil EngineeringBuilding Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 94 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf