umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Skillnader och samband mellan PaCO2 och ETCO2 i olika lägespositioner: En observationsstudie
Umeå University, Faculty of Medicine, Department of Nursing.
Umeå University, Faculty of Medicine, Department of Nursing.
2017 (Swedish)Independent thesis Advanced level (professional degree), 40 credits / 60 HE creditsStudent thesisAlternative title
Differences and correlations between PaCO2 and ETCO2 in different body positions : An observational study (English)
Abstract [sv]

ABSTRAKT

Syfte: Att undersöka skillnaden och samband mellan koldioxidvärden i artärblod (PaCO2) och utandningsluft (EtCO2) hos oralt intuberade intensivvårdspatienter i olika lägespositioner. Syftet var även att studera samband mellan differensen PaCO2-EtCO2 och tidalvolym.

Bakgrund: Intensivvårdssjuksköterskan är den som vanligen ansvarar över ventilationen och vändningar hos patienten som vårdas i respirator. Vändning sker oftast för att eftersträva god ventilation hos patienten. Respirationen styrs med hjälp av uppmätta koldioxidvärden som kontinuerligt kan mätas som EtCO2 och intermittent i artärblod som PaCO2. Det har visat sig att skillnaden mellan PaCO2 och EtCO2 kan variera beroende på position hos patienten på operationsavdelningar, men det saknas liknande studier på intensivvårdspatienter.

Design: Tvärsnittsdesign med kvantitativ ansats.

Metod: Data samlades in från 17 patienter på en intensivvårdsavdelning i norra Sverige under tre veckor år 2017. PaCO2, EtCO2 och tidalvolym mättes och dokumenterades i ett strukturerat protokoll. Differensen mellan PaCO2 och EtCO2 beräknades.

Resultat: Det fanns en signifikant skillnad mellan PaCO2 och EtCO2 i de olika lägespositionerna: rygg, z= -3,155, p=0,002; vänster z= -3,053, p=0,002; höger z=-3,294, p=0,001. Korrelationer hittades mellan PaCO2 och EtCO2 i ryggläge (r2 =0,506, p= 0,038) och högersidoläge (r2 =0,645, p= 0,009). Det påvisades också korrelationer mellan differensen (PaCO2-EtCO2) och tidalvolymen i högersidoläge (r2 = 0,604, p=0,017).

Konklusion: Studentarbetet har visat att PaCO2 och EtCO2 inte stämmer överens i olika lägespositioner. Resultatet visar att nya riktlinjer kan behövas för att intensivvårdssjuksköterskan ska känna sig trygg vid monitorering av EtCO2. Studentarbetet visar att mer forskning inom ämnet är nödvändigt då liknande forskning saknas.

Nyckelord: Intensivvård, PaCO2, EtCO2, monitorering, lägespositioner, omvårdnad, intensivvårdssjuksköterska

Abstract [en]

ABSTRACT

Aim: To study the difference and correlations between carbon dioxide in the arterial blood (PaCO2) and in the exhaled air (EtCO2) in orally intubated intensive care patients in different body positions. The aim was also to study the correlations between the difference PaCO2- EtCO2 and tidal volume.

Background: The critical care nurse (CCN) is usually responsible for the ventilation and the mobilization of the ventilator treated patient. Mobilization is generally done to seek good ventilation of the patient. Respiration is controlled by using carbon dioxide measurements continuously as EtCO2 and intermittent as PaCO2 in arterial blood. Studies have shown that difference between PaCO2 and EtCO2 can vary depending on body position of the patient in operating theatre. Similar studies on intensive care patients are lacking.

Design: A cross-sectional design, with a quantitative approach.

Method: Data was collected from 17 patients in an intensive care unit in north of Sweden during three weeks in year 2017. PaCO2, EtCO2 and tidal volume was measured and documented in a structured protocol. The difference between PaCO2 and EtCO2 was calculated.

Results: There was a significant difference between PaCO2 and EtCO2 in the different body positions: supine position z= -3,155, p=0,002; lateral left position z= -3,053, p=0,002; lateral right position z=-3,294, p=0,001. Correlations was found between PaCO2 and EtCO2 in supine position (r2 =0,506, p= 0,038) and lateral right position (r2 =0,645, p= 0,009). Correlation was also found between the difference (PaCO2-EtCO2) and tidal volume in lateral right position (r2 = 0,604, p=0,017).

Conclusion: This paper has shown that PaCO2 and EtCO2 do not always match in different body positions. The result indicates that new guidelines may be needed for the CCN to feel secure in monitoring EtCO2. There’s a lack of similar studies and the subject need more research.

Keywords: Intensive care, PaCO2, EtCO2, monitoring, body positions, nursing, critical care nurse

Place, publisher, year, edition, pages
2017. , p. 28
Keywords [en]
Intensive care, PaCO2, EtCO2, monitoring, body positions, nursing, critical care nurse
Keywords [sv]
Intensivvård, PaCO2, EtCO2, monitorering, lägespositioner, omvårdnad, intensivvårdssjuksköterska
National Category
Nursing
Identifiers
URN: urn:nbn:se:umu:diva-144278OAI: oai:DiVA.org:umu-144278DiVA, id: diva2:1178486
Educational program
Graduate Programme in Intensive Care Nursing; Graduate Programme in Intensive Care Nursing
Presentation
2018-01-11, Tandläkarhuset, plan 9, sal D, Umeå, 10:50 (Swedish)
Supervisors
Examiners
Available from: 2018-02-20 Created: 2018-01-29 Last updated: 2018-02-20Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Department of Nursing
Nursing

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 387 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf