The Short Cosyntropin Test Revisited: New Normal Reference Range Using LC-MS/MS
Show others and affiliations
2018 (English)In: Journal of Clinical Endocrinology and Metabolism, ISSN 0021-972X, E-ISSN 1945-7197, Vol. 103, no 4, p. 1696-1703Article in journal (Refereed) Published
Abstract [en]

Background: The cosyntropin test is used to diagnose adrenal insufficiency (AI) and nonclassical congenital adrenal hyperplasia (NCCAH). Current cutoffs for cortisol and 17-hydroxyprogesterone (17-OHP) are derived from nonstandardized immunoassays. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers direct measurement of steroids, prompting the need to re-establish normal ranges. Objective: The goal of this study was to define cutoff values for cortisol and 17-OHP in serum by LC-MS/MS 30 and 60 minutes after intravenous administration of 250 µg tetracosactide acetate to healthy volunteers and to compare the results with LC-MS/MS with routine immunoassays. Methods: Cosyntropin testing was performed in healthy subjects (n = 138) and in patients referred for evaluation of adrenocortical function (n = 94). Steroids were assayed by LC-MS/MS and compared with two immunoassays used in routine diagnostics (Immulite and Roche platforms). The cutoff level for cortisol was defined as the 2.5% percentile in healthy subjects not using oral estrogens (n = 121) and for 17-OHP as the 97.5% percentile. Results: Cortisol cutoff levels for LC-MS/MS were 412 and 485 nmol/L at 30 and 60 minutes, respectively. Applying the new cutoffs, 13 of 60 (22%) subjects who had AI according to conventional criteria now had a normal test result. For 17-OHP, the cutoff levels were 8.9 and 9.0 nmol/L at 30 and 60 minutes, respectively. Conclusions: LC-MS/MS provides cutoff levels for cortisol and 17-OHP after cosyntropin stimulation that are lower than those based on immunoassays, possibly because cross-reactivity between steroid intermediates and cortisol is eliminated. This reduces the number of false-positive tests for AI and false-negative tests for NCCAH.

Place, publisher, year, edition, pages
Oxford University Press, 2018. Vol. 103, no 4, p. 1696-1703
National Category
Endocrinology and Diabetes
Identifiers
URN: urn:nbn:se:umu:diva-147341DOI: 10.1210/jc.2017-02602ISI: 000429442000054PubMedID: 29452421OAI: oai:DiVA.org:umu-147341DiVA, id: diva2:1205421
Available from: 2018-05-14 Created: 2018-05-14 Last updated: 2018-06-09Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records BETA

Dahlqvist, Per

Search in DiVA

By author/editor
Dahlqvist, Per
By organisation
Department of Public Health and Clinical Medicine
In the same journal
Journal of Clinical Endocrinology and Metabolism
Endocrinology and Diabetes

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf