A study of thermal comfort enhancement using three energy efficient personalized heating strategies at two low indoor temperatures
Show others and affiliations
2018 (English)In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 143, p. 1-14Article in journal, Editorial material (Refereed) Published
Abstract [en]

There is great potential to apply personalized heating for saving energy and enhancing individual thermal comfort in buildings during cold weather. This study investigated the enhancement of thermal comfort of occupants using personalized heating systems at low indoor temperatures. Three personalized heating systems are chosen for this work, i.e., a radiant heating panel with a heated table pad (denoted as HB1), a heated chair with a heated floor mattress (denoted as HB2), and electrical heating clothing (a heated jacket and trousers, denoted as EHC). The effectiveness of three selected heating systems on overall/local body thermal comfort of female occupants under two indoor temperatures of 15 and 18 degrees C has been investigated. Total energy consumption of these heating systems has also been examined and compared. Thermal acceptability of EHC was better than HB1 and HB2 at both two temperatures. Overall thermal sensation vote (TSV) in EHC was significantly better than that in HB1. Mean skin temperature remained within the thermal comfort range (32-34 degrees C). In order to achieve thermal comfort on 70% and 80% of the inhabitants at various body parts, local body TSVs should be within - 0.43 to 1.87 and - 0.36 to 1.87, respectively. Further, EHC consumed < 15 W power, which accounts for only 4.4% and 14.8% of the total power consumed by HB1 and HB2, respectively. Based on the evidenced thermal comfort improvement potential and low power consumption in EHC, it is thus recommended to use EHC for the thermal comfort enhancement of inhabitants under low indoor temperatures.

Place, publisher, year, edition, pages
Pergamon Press, 2018. Vol. 143, p. 1-14
Keywords [en]
Thermal comfort, Electrical heating clothing, Radiant heating panel, Heated chair, Heating floor mattress, Energy saving
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:umu:diva-149588DOI: 10.1016/j.buildenv.2018.06.049ISI: 000445987100001OAI: oai:DiVA.org:umu-149588DiVA, id: diva2:1222982
Available from: 2018-06-24 Created: 2018-06-24 Last updated: 2018-10-31Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Search in DiVA

By author/editor
Yang, Bin
By organisation
Department of Applied Physics and Electronics
In the same journal
Building and Environment
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 97 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf