umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Robust Methods for Automated Selection of Cardiac Signals After Blind Source Separation
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: IEEE Transactions on Biomedical Engineering, ISSN 0018-9294, E-ISSN 1558-2531, Vol. 65, nr 10, s. 2248-2258Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: Novel minimum-contact vital signs monitoring techniques like textile or capacitive electrocardiogram (ECG) provide new opportunities for health monitoring. These techniques are sensitive to artifacts and require handling of unstable signal quality. Spatio-temporal blind source separation (BSS) is capable of processing suchlike multichannel signals. However, BSS's permutation indeterminacy requires the selection of the cardiac signal (i.e., the component resembling the electric cardiac activity) after its separation from artifacts. This study evaluates different concepts for solving permutation indeterminacy.

Methods: Novel automated component selection routines based on heartbeat detections are compared with standard concepts, as using higher order moments or frequency-domain features, for solving permutation indeterminacy in spatio-temporal BSS. BSS was applied to a textile and a capacitive ECG dataset of healthy subjects performing a motion protocol, and to the MIT-BIH Arrhythmia Database. The performance of the subsequent component selection was evaluated by means of the heartbeat detection accuracy (ACC) using an automatically selected single component.

Results: The proposed heartbeat-detection-based selection routines significantly outperformed the standard selectors based on Skewness, Kurtosis, and frequency-domain features, especially for datasets containing motion artifacts. For arrhythmia data, beat analysis by sparse coding outperformed simple periodicity tests of the detected heartbeats. Conclusion: Component selection routines based on heartbeat detections are capable of reliably selecting cardiac signals after spatio-temporal BSS in case of severe motion artifacts and arrhythmia.

Significance: The availability of robust cardiac component selectors for solving permutation indeterminacy facilitates the usage of spatio-temporal BSS to extract cardiac signals in artifact-sensitive minimum-contact vital signs monitoring techniques.

Ort, förlag, år, upplaga, sidor
Institute of Electrical and Electronics Engineers (IEEE), 2018. Vol. 65, nr 10, s. 2248-2258
Nyckelord [en]
Biomedical signal processing, blind source separation, cardiac signals, electrocardiogram, dependent component analysis, permutation indeterminacy, sparse coding, spatio-temporal processing
Nationell ämneskategori
Datavetenskap (datalogi)
Identifikatorer
URN: urn:nbn:se:umu:diva-152393DOI: 10.1109/TBME.2017.2788701ISI: 000445233200013PubMedID: 29993470OAI: oai:DiVA.org:umu-152393DiVA, id: diva2:1254139
Forskningsfinansiär
Vetenskapsrådet, 2015-04677Tillgänglig från: 2018-10-08 Skapad: 2018-10-08 Senast uppdaterad: 2018-10-08Bibliografiskt granskad

Open Access i DiVA

fulltext(1516 kB)139 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1516 kBChecksumma SHA-512
c2abd1615c420759dea57998954cae5f8e8b90adf352e708c8ac4fcb22b504261c210ae2de0f194591c048d5e48713bd80e8b248b6d773df34316c06b31150b4
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Wiklund, Urban

Sök vidare i DiVA

Av författaren/redaktören
Wiklund, Urban
Av organisationen
Radiofysik
I samma tidskrift
IEEE Transactions on Biomedical Engineering
Datavetenskap (datalogi)

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 139 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 132 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf