Sol-air thermometer measurement of heat transfer coefficient at building outdoor surface
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
2018 (Engelska)Ingår i: Cold Climate HVAC 2018: Sustainable Buildings in Cold Climates, Springer, 2018, s. 329-338Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

There exists a building energy performance gap between theoretical simulations and the actual energy usage as measured. One potential reason for this gap might be a mismatch between predicted and measured values of the heat flux q through the building envelope. There is therefore a need to develop accurate and more cost-efficient methods for measurement of q. The standard ISO 9869-1 states that, at the outdoor surface, q = ho(Ts − Tenv), where ho is the overall heat transfer coefficient, including both convective and radiative components, Tenv is the environmental temperature, and Ts is the temperature of the building surface. It has previously been shown that the sol-air thermometer (SAT) could be used for convenient measurement of Tenv under dark conditions. In the present work, two SAT units, one heated and the other unheated, were employed for accurate outdoor measurements of ho in cold winter climate. Validation was performed by comparison of results from the new method against measurements, where previously established methodology was used. With current operating conditions, the measurement uncertainty was estimated to be 3.0 and 4.4%, for ho equal to 13 and 29 Wm−2K−1, respectively. The new SAT steady-state method is more cost-effective compared to previous methodology, in that the former involves fewer input quantities (surface emissivity and infrared radiation temperature are unnecessary) to be measured, while giving the same ho results, without any sacrifice in accuracy. SAT methodology thus enables measurement of both Tenv and ho, which characterizes the building thermal environment, and supports estimation of q.

Ort, förlag, år, upplaga, sidor
Springer, 2018. s. 329-338
Serie
Springer Proceedings in Energy
Nyckelord [en]
Heat transfer coefficient, Sol-air thermometer, Environmental temperature, Building energy performance gap
Nationell ämneskategori
Samhällsbyggnadsteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-152725DOI: 10.1007/978-3-030-00662-4_28OAI: oai:DiVA.org:umu-152725DiVA, id: diva2:1257460
Konferens
CONFERENCE on 9th International Cold Climate HVAC 2018, Kiruna, Sweden, March 12-15, 2018
Tillgänglig från: 2018-10-21 Skapad: 2018-10-21 Senast uppdaterad: 2019-06-19Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Ohlsson, K.E. AndersÖstin, RonnyOlofsson, Thomas

Sök vidare i DiVA

Av författaren/redaktören
Ohlsson, K.E. AndersÖstin, RonnyOlofsson, Thomas
Av organisationen
Institutionen för tillämpad fysik och elektronik
Samhällsbyggnadsteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 74 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf