Stråldosreducerande åtgärder: med bibehållen bildkvalitet vid datortomografiundersökningar av thorax eller buk
Umeå University, Faculty of Medicine, Department of Nursing.
2019 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Radiation dose reduction methods : with preserved image quality during computed tomography examinations of the chest or abdomen (English)
Abstract [sv]

Abstrakt

Stråldosreducerande åtgärder

med bibehållen bildkvalitet vid datortomografiundersökningar av thorax eller buk

Bakgrund: Datortomografins (DT) fördelar är bland annat bra diagnostiska bilder på olika organ och en kort undersökningstid. Detta är en bidragande faktor till att DT-undersökningar har ökat markant senaste 20 åren. Idag bidrar DT-undersökningar med mest strålning inom bild- och funktionsmedicin.

 

Syfte: Litteraturstudiens syfte var att sammanställa stråldos-begränsningar i form av tekniska parametrarna rörspänning (kV) och rörladdning (mAs) och dess inverkan på patientstråldos och bildkvalité vid datortomografiundersökningar av thorax eller buk.

 

Metod: Litteraturstudien inkluderade tolv artiklar med kvantitativ ansats som svarade mot syftet. Artiklarna kvalitet granskades först av författarna och analyserades sedan. PubMed och CINAHL användes som aktuella databaser för artikel-sökningarna.

 

Resultat: Resultatet kategoriserades i två huvudkategorier, studier om bukundersökningar och studier om thoraxundersökningar. Resultatet visar att justerad kV och mAs utifrån patientens vikt, BMI eller kroppsomfång kan ha en positiv effekt för patienten utan att påverka bildkvaliteten så att diagnostiken blir osäker.

 

Konklusion: Ändring av tekniska parametrar (kV och mAs) vid DT thorax- och buk-undersökningar kan resultera i en minskad stråldos till patienten med bibehållen godkänd diagnostisk bildkvalitet, framför allt om hänseende till patientens vikt, BMI eller kroppsform tas.

Abstract [en]

Abstract

Radiation dose reduction methods

with preserved image quality during computed tomography examinations of the chest or abdomen

 

Background: Important computed tomography (CT) advantages are for instance good diagnostic images of different organs and short examination time. These are contributing factors to why CT examinations have increased rapidly over the last 20 years. Today, CT examinations contributes with the highest radiation dose of all modalities within X-ray departments.

 

Aim: The literature reviews aim was to compile radiation dose restrictions regarding computed tomography examinations of the chest or abdomen by taking into account the technical parameters tube voltage (kV) and milliampere second (mAs) and their effect on patient radiation dose and CT image quality.

 

Method: The literature review included twelve articles with a quantitative method that met the aim. The articles quality was assessed first by the authors and analyzed later. PubMed and CINAHL were the databases used for the article search.

 

Results: The result was categorized into two main headings, studies involving abdominal examinations and studies involving chest examinations. The result shows that adjusted kV and mAs based on the patient’s weight, BMI or body configuration could have a positive effect for the patient without affecting the image quality so the diagnosis becomes uncertain.

 

Conclusion: Adjustment of technical parameters (kV and mAs) with optimization for patient body weight, BMI or body configuration, regarding CT chest and CT abdominal examinations can result in a reduction of radiation dose to the patient with preserved acceptable diagnostic image quality.

 

Place, publisher, year, edition, pages
2019. , p. 49
Keywords [en]
Computed tomography, Parameters, Radiation dose, Image quality, Chest, Abdominal
Keywords [sv]
Datortomografi, Parametrar, Stråldos, Bildkvalitet, Thorax, Buk
National Category
Nursing
Identifiers
URN: urn:nbn:se:umu:diva-159118OAI: oai:DiVA.org:umu-159118DiVA, id: diva2:1316490
Educational program
Diagnostic Radiology Nursing Programme
Presentation
2019-05-02, Sal 260 Röntgen NUS, Umeå, 15:20 (Swedish)
Supervisors
Available from: 2019-06-19 Created: 2019-05-18 Last updated: 2019-06-19Bibliographically approved

Open Access in DiVA

No full text in DiVA

Search in DiVA

By author/editor
Filler, Jakob
By organisation
Department of Nursing
Nursing

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 3 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf