Method to estimate the ground loads for missing periods in a monitored GSHP
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.ORCID iD: 0000-0003-3115-4195
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.ORCID iD: 0000-0002-8704-8538
2019 (English)In: EUROPEAN GEOTHERMAL CONGRESS 2019: THE HAGUE, 11-14 JUNE 2019, 2019Conference paper, Poster (with or without abstract) (Other academic)
Abstract [en]

Monitoring a ground source heat pump can provide important insights into its working, but to study the behaviour of the borehole heat exchanger (BHE) we require monitored data for the whole period of operation. In practice, the monitored data often has periods of missing data. We propose a method to estimate the load during the periods of missing data based on the fluid temperature after that period. The method determined the missing load with negligible error, for the case of a BHE that behaves exactly like the model describing it. A sensitivity analysis showed that the estimated load is highly sensitive to errors in measured load and fluid temperature. The method was applied to a real monitored BHE, the magnitude of estimated loads were unreasonably high, but the overall deviation between the measured and simulated values of fluid temperature decreased. Therefore, the high magnitude of missing load compensates for the lack of agreement between the model and the measured data.

Place, publisher, year, edition, pages
2019.
Keywords [en]
ground source heat pump, borehole heat exchanger, monitored, missing loads.
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:umu:diva-160966OAI: oai:DiVA.org:umu-160966DiVA, id: diva2:1331051
Conference
European Geothermal Congress, The Hague, The Netherlands, June 11-14, 2019
Available from: 2019-06-26 Created: 2019-06-26 Last updated: 2019-06-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records BETA

Puttige, Anjan RaoAndersson, StaffanÖstin, RonnyOlofsson, Thomas

Search in DiVA

By author/editor
Puttige, Anjan RaoAndersson, StaffanÖstin, RonnyOlofsson, Thomas
By organisation
Department of Applied Physics and Electronics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 10 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf