umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Semi-automatic method for segmentation of the internal jugular vein in ultrasound movies evaluated at different body postures
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.ORCID-id: 0000-0001-5317-4563
Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Biomedical Physics & Engineering Express, E-ISSN 2057-1976, Vol. 5, nr 4, artikel-id 045034Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: The collapse of the internal jugular vein (IJV) regulates intracranial pressure (ICP) in upright body positions. The cross-section area (CSA) is therefore of interest when studying the effects of postural changes in various neurological diseases. We have developed a semi-automatic segmentation method, which tracks the CSA of the IJV in ultrasound movies, and evaluated its performance in three body positions (supine, 16°, 71°). Approach: The proposed method utilized post-processing image filtering combined with a modified snake active contour algorithm. The ultrasound movies were retrospectively analysed (n = 231, 3s, 28 fps) based on previously collected data from 17 healthy volunteers. The computed CSAs (CA) from the segmentation method were compared to manually segmented CSAs (MA) in two frames per movie. Tracking performance were evaluated by visual inspection. Main results: In the supine position, 100% of the ultrasound movies were tracked successfully, and the mean of CA-MA was −4.4 ± 6.9 mm2 (MA, 88.4 ± 50.5 mm2). The most challenging movies occurred in upright body posture where tracking success rate was 90% and mean of CA-MA was −1.4 ± 2.2 mm2 (MA, 12.0 ± 11.1 mm2). The semi-automatic segmentations took 55 s to perform on average (per movie) compared to manual segmentations which took 50 min. Significance: Segmentations made by the proposed method were comparable to manual segmentations in all tilt-angles, however much faster. Efficient and accurate tracking of the CSA of the IJV, with respect to postural changes, could help furthering our understanding of how IJV-biomechanics relates to regulation of intracranial pressure in different neurological diseases and physiological states.

Ort, förlag, år, upplaga, sidor
Institute of Physics Publishing (IOPP), 2019. Vol. 5, nr 4, artikel-id 045034
Nyckelord [en]
posture, intracranial pressure, ultrasound, jugular veins, computer-assisted image analysis
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-161912DOI: 10.1088/2057-1976/ab285eISI: 000475798800001OAI: oai:DiVA.org:umu-161912DiVA, id: diva2:1340970
Tillgänglig från: 2019-08-07 Skapad: 2019-08-07 Senast uppdaterad: 2019-11-28Bibliografiskt granskad

Open Access i DiVA

fulltext(3187 kB)82 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 3187 kBChecksumma SHA-512
51be7cf3e8d1003deb5e12b6200bca5147a518b7bf8e7a266186971f6f1fa46e6a5dfe1ad7727778e0d96403ead53267fd03532d100763a595bdd40b74b0dd4b
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Personposter BETA

Westlund, ArvidHolmlund, PetterJohansson, EliasMalm, JanEklund, Anders

Sök vidare i DiVA

Av författaren/redaktören
Westlund, ArvidHolmlund, PetterJohansson, EliasMalm, JanEklund, Anders
Av organisationen
Institutionen för strålningsvetenskaperKlinisk neurovetenskap
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 82 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 251 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf