umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Assessment of Cerebral Blood Flow Pulsatility and Cerebral Arterial Compliance With 4D Flow MRI
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.ORCID-id: 0000-0002-1315-7010
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI).ORCID-id: 0000-0001-6784-1945
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper. Umeå universitet, Medicinska fakulteten, Umeå centrum för funktionell hjärnavbildning (UFBI). Umeå universitet, Samhällsvetenskapliga fakulteten, Enheten för demografi och åldrandeforskning (CEDAR).ORCID-id: 0000-0002-5911-9511
Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap.ORCID-id: 0000-0001-6451-1940
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586Artikel i tidskrift (Refereegranskat) Epub ahead of print
Abstract [en]

BACKGROUND: Four-dimensional flow magnetic resonance imaging (4D flow MRI) enables efficient investigation of cerebral blood flow pulsatility in the cerebral arteries. This is important for exploring hemodynamic mechanisms behind vascular diseases associated with arterial pulsations.

PURPOSE: To investigate the feasibility of pulsatility assessments with 4D flow MRI, its agreement with reference two-dimensional phase-contrast MRI (2D PC-MRI) measurements, and to demonstrate how 4D flow MRI can be used to assess cerebral arterial compliance and cerebrovascular resistance in major cerebral arteries.

STUDY TYPE: Prospective.

SUBJECTS: Thirty-five subjects (20 women, 79 ± 5 years, range 70-91 years).

FIELD STRENGTH/SEQUENCE: 4D flow MRI (PC-VIPR) and 2D PC-MRI acquired with a 3T scanner.

ASSESSMENT: Time-resolved flow was assessed in nine cerebral arteries. From the pulsatile flow waveform in each artery, amplitude (ΔQ), volume load (ΔV), and pulsatility index (PI) were calculated. To reduce high-frequency noise in the 4D flow MRI data, the flow waveforms were low-pass filtered. From the total cerebral blood flow, total PI (PItot ), total volume load (ΔVtot ), cerebral arterial compliance (C), and cerebrovascular resistance (R) were calculated.

STATISTICAL TESTS: Two-tailed paired t-test, intraclass correlation (ICC).

RESULTS: There was no difference in ΔQ between 4D flow MRI and the reference (0.00 ± 0.022 ml/s, mean ± SEM, P = 0.97, ICC = 0.95, n = 310) with a cutoff frequency of 1.9 Hz and 15 cut plane long arterial segments. For ΔV, the difference was -0.006 ± 0.003 ml (mean ± SEM, P = 0.07, ICC = 0.93, n = 310) without filtering. Total R was 11.4 ± 2.41 mmHg/(ml/s) (mean ± SD) and C was 0.021 ± 0.009 ml/mmHg (mean ± SD). ΔVtot was 1.21 ± 0.29 ml (mean ± SD) with an ICC of 0.82 compared with the reference. PItot was 1.08 ± 0.21 (mean ± SD).

DATA CONCLUSION: We successfully assessed 4D flow MRI cerebral arterial pulsatility, cerebral arterial compliance, and cerebrovascular resistance. Averaging of multiple cut planes and low-pass filtering was necessary to assess accurate peak-to-peak features in the flow rate waveforms.

LEVEL OF EVIDENCE: 2

Technical Efficacy Stage: 2

J. Magn. Reson. Imaging 2019.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell, 2019.
Nyckelord [en]
2D PC-MRI, 4D flow MRI, cerebral arterial compliance, cerebrovascular resistance, circle of Willis, pulsatility index
Nationell ämneskategori
Medicinteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-165203DOI: 10.1002/jmri.26978ISI: 000495792500001PubMedID: 31713964OAI: oai:DiVA.org:umu-165203DiVA, id: diva2:1371775
Forskningsfinansiär
Vetenskapsrådet, 2015–05616Hjärt-Lungfonden, 20140592Vetenskapsrådet, 2017-04949Tillgänglig från: 2019-11-20 Skapad: 2019-11-20 Senast uppdaterad: 2019-12-10

Open Access i DiVA

fulltext(622 kB)19 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 622 kBChecksumma SHA-512
1fe8b0bb1ed1973a74ce7f08ec8ff4f0de353cd9bf2ad20fbc14a20f5f6b90b6b52c24fb7bb107ec59cec1bf9273276a45e37276906cbece5189b264fe3b4d9b
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Holmgren, MadeleneWåhlin, AndersDunås, ToraMalm, JanEklund, Anders

Sök vidare i DiVA

Av författaren/redaktören
Holmgren, MadeleneWåhlin, AndersDunås, ToraMalm, JanEklund, Anders
Av organisationen
Institutionen för strålningsvetenskaperUmeå centrum för funktionell hjärnavbildning (UFBI)Enheten för demografi och åldrandeforskning (CEDAR)Institutionen för farmakologi och klinisk neurovetenskap
I samma tidskrift
Journal of Magnetic Resonance Imaging
Medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 19 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 37 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf