Evaluation of a routine hematology analyzer for quality control of leukoreduced plasma
Umeå University, Faculty of Medicine, Department of Medical Biosciences, Clinical chemistry. Department of Research and Development, Region Kronoberg, Växjö.ORCID iD: 0000-0003-2844-1310
2019 (English)In: Transfusion, ISSN 0041-1132, E-ISSN 1537-2995, Vol. 9, no 10, p. 3214-3218Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: Quality control of residual white blood cells (WBCs) and red blood cells (RBCs) in leukoreduced plasma is mandatory. Although technological advances have been made, analysis of quality controls using routine hematology analyzers has not generally been introduced. The aim of this study was to evaluate if the routine hematology analyzer Sysmex XN‐10, (Sysmex Nordic ApS) could be used for quality control of residual WBCs and RBCs in leukoreduced plasma.

STUDY DESIGN AND METHODS: Linearity, accuracy, and precision were established for two Sysmex XN‐10 analyzers using spiked donor plasma. ADAM rWBC (NanoEnTek) and manual counting in the Bürker chamber (NanoEnTek) were reference methods for WBCs and RBCs, respectively. Twenty‐five consecutive leukoreduced donor plasma samples were also tested.

RESULTS: For WBCs, the linearity criteria were met for the ADAM rWBC, but not for the Sysmex XN‐10 instruments. Precision on both Sysmex XN‐10 instruments was accurate only at 6 cells/μL, and accuracy was consistently acceptable only at 5 to 6 cells/μL. The precision and accuracy of the ADAM rWBC were acceptable at 2 to 6 cells/μL.

For RBCs, both Sysmex XN‐10 instruments and manual counting in the Bürker chamber were linear and fulfilled the precision criteria. Accuracy was acceptable for both Sysmex instruments at 6 to 12 × 109 WBCs/L but fluctuated within the study's measuring range for the Bürker chamber.

No false‐positive results were seen in the 25 consecutive donor plasma samples tested.

CONCLUSION: For quality control purposes of leukoreduced plasma, the Sysmex XN‐10 analyzer is suitable for the enumeration of residual RBCs but not of residual WBCs.

Place, publisher, year, edition, pages
2019. Vol. 9, no 10, p. 3214-3218
National Category
Hematology
Identifiers
URN: urn:nbn:se:umu:diva-163074DOI: 10.1111/trf.15481ISI: 000481054500001PubMedID: 31400008OAI: oai:DiVA.org:umu-163074DiVA, id: diva2:1373471
Available from: 2019-11-27 Created: 2019-11-27 Last updated: 2019-11-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records BETA

Ekblom, Kim

Search in DiVA

By author/editor
Ekblom, Kim
By organisation
Clinical chemistry
In the same journal
Transfusion
Hematology

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 8 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf