Optimization of photon beam flatness for radiation therapy
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
2007 (English)In: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 52, no 6, 1735-1746 p.Article in journal (Refereed) Published
Abstract [en]

In this work, we investigate the relation between lateral fluence/dose distributions and photon beam uniformity, possibly identifying ways to improve these characteristics. The calculations included treatment head scatter properties associated with three common types of linear accelerators in order to study their impact on the results. For 6 and 18 MV photon beams the lateral fluence distributions were optimized with respect to the resulting calculated flatness, as defined by the International Electrotechnical Commission (IEC), at 10 cm depth in six different field sizes. The limits proposed by IEC for maximum dose ratios ('horns') at the depth of dose maximum have also been accounted for in the optimization procedure. The conclusion was that typical head scatter variations among different types of linear accelerators have a very limited effect on the optimized results, which implies that the existing differences in measured off- axis dose distributions are related to non- equivalent optimization objectives. Finally, a comparison between the theoretically optimized lateral dose distributions and corresponding dose measurements for the three investigated accelerator types was performed. Although the measured data generally fall within the IECrequirements the optimized distributions show better results overall for the evaluated uniformity parameters, indicating that there is room for improved flatness performance in clinical photon beams.

Place, publisher, year, edition, pages
2007. Vol. 52, no 6, 1735-1746 p.
Identifiers
URN: urn:nbn:se:umu:diva-5256DOI: 10.1088/0031-9155/52/6/013OAI: oai:DiVA.org:umu-5256DiVA: diva2:144710
Available from: 2006-08-31 Created: 2006-08-31 Last updated: 2011-03-25Bibliographically approved
In thesis
1. Developing and evaluating dose calculation models for verification of advanced radiotherapy
Open this publication in new window or tab >>Developing and evaluating dose calculation models for verification of advanced radiotherapy
2006 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

A prerequisite for modern radiotherapy is the ability to accurately determine the absorbed dose (D) that is given to the patient. The subject of this thesis has been to develop and evaluate efficient dose calculation models for high-energy photon beams delivered by linear accelerators. Even though the considered calculation models are general, the work has been focused on quality assurance (QA) tools used to independently verify the dose for individual treatment plans. The purpose of this verification is to guarantee patient safety and to improve the treatment outcome. Furthermore, a vital part of this work has been to explore the prospect of estimating the dose calculation uncertainties associated with individual treatment setups. A discussion on how such uncertainty estimations can facilitate improved clinical QA procedures by providing appropriate action levels has also been included within the scope of this thesis.

In order to enable efficient modelling of the physical phenomena that are involved in dose output calculations it is convenient to divide them into two main categories; the first one dealing with the radiation exiting the accelerator’s treatment head and a second one associated with the subsequent energy deposition processes. A multi-source model describing the distribution of energy fluence emitted from the treatment head per delivered monitor unit (MU) is presented and evaluated through comparisons with measurements in multiple photon beams and collimator settings. The calculations show close agreement with the extensive set of experimental data, generally within +/-1% of corresponding measurements.

The energy (dose) deposition in the irradiated object has been modelled through a photon pencil kernel solely based on a beam quality index (TPR20,10). This model was evaluated in a similar manner as the multi-source model at three different treatment depths. A separate study was focused on the specific difficulties associated with dose calculations in points located at a distance from the central beam axis. Despite the minimal input data required to characterize individual photon beams, the accuracy proved to be very good when comparing the calculated results with experimental data.

The evaluated calculation models were finally used to analyse how well the lateral dose distributions from typical megavoltage photon beams are optimized with respect to the resulting beam flatness characteristics. The results did not reveal any obvious reasons why different manufacturers should provide different lateral dose distributions. Furthermore, the performed lateral optimizations indicate that there is room for improved flatness performance for the investigated linear accelerators.

Place, publisher, year, edition, pages
Umeå: Umeå universitet, 2006. 50 p.
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 1044
Keyword
Radiation therapy, high-energy photons, dose calculation, multi-source model, pencil kernel, uncertainties, action levels
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:umu:diva-841 (URN)91-7264-141-X (ISBN)
Public defence
2006-09-22, 244, 7, Norrlands universitetssjukhus, Umeå, 13:00 (English)
Opponent
Supervisors
Available from: 2006-08-31 Created: 2006-08-31 Last updated: 2012-04-03Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Olofsson, JörgenNyholm, TufveKarlsson, Mikael

Search in DiVA

By author/editor
Olofsson, JörgenNyholm, TufveAhnesjö, AndersKarlsson, Mikael
By organisation
Radiation Physics
In the same journal
Physics in Medicine and Biology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 144 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf