Conditions for Accurate Karl Fischer Coulometry Using Diaphragm-Free Cells
Umeå University, Faculty of Science and Technology, Department of Chemistry.
Umeå University, Faculty of Science and Technology, Department of Chemistry.
2000 (English)In: Analytical Chemistry, ISSN 0003-2700, E-ISSN 1520-6882, Vol. 72, no 1, 172-179 p.Article in journal (Refereed) Published
Abstract [en]

Factors influencing the extent of formation of oxidizable reduction products in coulometric cells used for Karl Fischer (KF) determination of water were investigated. For methanolic KF reagents buffered with imidazole (Im) or diethanolamine (DEA) (separately or in combination), three parameters were found to be of outmost importance: the cathodic current density, the pH, and the concentration of protonated base (ImH+ or DEAH+). For reagents buffered with only Im, the relative formation of oxidizable reduction products varied in the range 2-40%; i.e., 51-70 g of water was found for a 50 g water sample, depending on the above-mentioned parameters. The lowest values were observed for reagents having a pH around 10 in combination with cathodic current densities in the range 2000-5000 mA cm-2. For all the Im-buffered reagents investigated, the addition of modifiers such as chloroform, hexanol, and carbon tetrachloride was found to decrease the formation of oxidizable reduction products significantly. For example, a reagent buffered at pH 10 containing 1 M hexanol gave less than 0.3% formation in the current density interval from 200 to 4000 mA cm-2. The best reagents based on the above-mentioned modifiers were tested in the continuous coulometric mode with errors typically in the interval 0-0.5% using optimum conditions. One prerequisite for obtaining such small errors with diaphragm-free continuous coulometry is to use a cathode area no larger than 0.002 cm2. For some of the reagents based on both Im and DEA, the formation of oxidizable reduction products was close to zero at certain current densities, although the analytical performance was not as good as for the reagents buffered solely by Im due to longer conditioning and titration times.

Place, publisher, year, edition, pages
Washington, D. C., USA: American Chemical Society , 2000. Vol. 72, no 1, 172-179 p.
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:umu:diva-8502DOI: 10.1021/ac990594sOAI: oai:DiVA.org:umu-8502DiVA: diva2:148173
Available from: 2008-01-25 Created: 2008-01-25 Last updated: 2017-12-14Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Nordmark, UlrikaCedergren, Anders
By organisation
Department of Chemistry
In the same journal
Analytical Chemistry
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 47 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf