umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Surface roughness of five different dental ceramic core materials after grinding and polishing
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi, Odontologisk materialvetenskap.
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi, Protetik.
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi, Odontologisk materialvetenskap.
2006 (Engelska)Ingår i: Journal of Oral Rehabilitation, ISSN 0305-182X, E-ISSN 1365-2842, Vol. 33, nr 2, s. 117-124Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In clinical practice, core materials can be exposed after adjustments are made to previously-luted all-ceramic restorations. The purpose of this study was to evaluate the surface roughness of five different dental ceramic core materials after grinding and polishing. Five different ceramic core materials, Vita In-Ceram Alumina, Vita In-Ceram Zirconia, IPS Empress 2, Procera AllCeram, and Denzir were evaluated. Vita Mark II was used as a reference material. The surface roughness, Ra value (mum), was registered using a profilometer. The measurements were made before and after grinding with diamond rotary cutting instruments and after polishing with the Sof-Lex system. The surface of representative specimens was evaluated qualitatively using scanning electron microscopy (SEM). Results were statistically analysed using analysis of variance (anova) supplemented with Scheffe's and Bonferroni multiple-comparison tests. Before grinding, Procera AllCeram and Denzir had the smoothest surfaces, while IPS Empress 2 had the coarsest. After grinding, all materials except IPS Empress 2 became coarser. Polishing with Sof-Lex provided no significant (P > 0.05) differences between Denzir, Vita Mark II and IPS Empress 2 or between Procera AllCeram and In-Ceram Zirconia. There were no significant differences (P > 0.05) either between the ground and the polished Procera AllCeram or In-Ceram Alumina specimens. Polishing of Denzir, IPS Empress 2 and In-Ceram Zirconia made the surfaces smoother compared with the state after grinding, whereas the polishing effect on Procera AllCeram and In-Ceram Alumina was ineffective. The findings of the SEM evaluation were consistent with the profilometer readings.

Ort, förlag, år, upplaga, sidor
2006. Vol. 33, nr 2, s. 117-124
Nyckelord [en]
all-ceramic crowns, alumina, dental ceramics, dental polishing, finishing, lithium disilicate, Y-TZP, zirconia
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:umu:diva-12427DOI: 10.1111/j.1365-2842.2006.01546.xPubMedID: 16457671OAI: oai:DiVA.org:umu-12427DiVA, id: diva2:152098
Tillgänglig från: 2007-12-13 Skapad: 2007-12-13 Senast uppdaterad: 2018-06-09Bibliografiskt granskad
Ingår i avhandling
1. On dental ceramics and their fracture: a laboratory and numerical study
Öppna denna publikation i ny flik eller fönster >>On dental ceramics and their fracture: a laboratory and numerical study
2010 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Background Surface treatments and irregularities in the surfaces may affect the fracture of ceramics. The effects of various treatments on the surface texture of different types of ceramic cores/substructures was therefore qualitatively, quantitatively and numerically evaluated. Since fractures in ceramics are not fully understood, the fracture behavior in dental ceramic core/substructures was also studied using both established laboratory methods and newly developed numerical methods.

Methods The surfaces of dental ceramic cores/substructures were studied qualitatively by means of a fluorescence penetrant method and scanning electron microscopy, quantitatively evaluated using a profilometer and also numerical simulation. In order to study fracture in zirconia-based fixed partial denture (FPD) frameworks, fractographic analysis in combination with fracture tests and newly developed two-dimensional (2D) and three-dimensional (3D) numerical modeling methods were used. In the numerical modeling methods, the heterogeneity within the materials was described by means of the Weibull distribution law. The Mohr–Coulomb failure criterion with tensile strength cut-off was used to judge whether the material was in an elastic or failed state.

Results Manual grinding/polishing could smooth the surfaces on some of the types of dental ceramic cores/substructures studied. Using the fluorescence penetrant method, no cracks/flaws apart from milling grooves could be seen on the surfaces of machined zirconia-based frameworks. Numerical simulations demonstrated that surface grooves affect the fracture of the ceramic bars and the deeper the groove, the sooner the bar fractured. In the laboratory tests the fracture mechanism in the FPD frameworks was identified as tensile failure and irregularities on the ceramic surfaces could act as fracture initiation sites. The numerical modeling codes allowed a better understanding of the fracture mechanism than the laboratory tests; the stress distribution and the fracture process could be reproduced using the mathematical methods of mechanics. Furthermore, a strong correlation was found between the numerical and the laboratory results.

Conclusion Based on the findings in the current thesis, smooth surfaces in areas of concentrated tensile stress would be preferable regarding the survival of ceramic restorations, however, the surfaces of only some of the ceramic cores/substructures could be significantly affected by manual polishing. The newly developed 3D method clearly showed the stress distribution and the fracture process in ceramic FPD frameworks, step by step, and seems to be an appropriate tool for use in the prediction of the fracture process in ceramic FPD frameworks.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå universitet, 2010. s. 53
Serie
Umeå University odontological dissertations, ISSN 0345-7532 ; 113
Nyckelord
Dental ceramics, Finite element analysis, Fixed partial denture, Fracture, Numerical modeling, Surface treatment
Nationell ämneskategori
Biomaterialvetenskap
Forskningsämne
odontologi
Identifikatorer
urn:nbn:se:umu:diva-36590 (URN)978-91-7459-037-1 (ISBN)
Disputation
2010-10-29, Sal 260, byggnad 3A, Norrlands universitetssjukhus, Umeå, 13:00 (Svenska)
Opponent
Handledare
Tillgänglig från: 2010-10-08 Skapad: 2010-10-05 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Kou, WenMolin, MargaretaSjögren, Göran

Sök vidare i DiVA

Av författaren/redaktören
Kou, WenMolin, MargaretaSjögren, Göran
Av organisationen
Odontologisk materialvetenskapProtetik
I samma tidskrift
Journal of Oral Rehabilitation
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 631 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf