A chemiluminescence flow immunosensor based on a porous monolithic metacrylate and polyethylene composite disc modified with Protein G
Show others and affiliations
2004 (English)In: Biosensors and Bioelectronics, Vol. 19, no 8, 795-803 p.Article in journal (Refereed) Published
Abstract [en]

A generic, fast, sensitive and new type of flow immunosensor has been developed. The basis is a monolithic porous poly(glycidyl methacrylate-co-trimethylolpropane trimethacrylate) polymer disc modified with protein G, placed in a fountain type flow cell compartment, in close proximity to a photomultiplier tube (PMT). Analyte and HRP labelled analyte derivative (tracer) compete for anti-analyte antibody binding sites. The mixture is then injected into the flow immunosensor system where the formed analyte- and tracer-antibody complexes are trapped by the monolithic protein G disc. The amount of bound tracer, inversely related to the concentration of analyte in the sample, is determined in a second step by injection of luminol, p-iodophenol and H2O2, generating enhanced chemiluminescence (CL) with horseradish peroxidase (HRP). A third and final step is need for regeneration of the protein G disc so that a new analysis cycle can take place. The performance of the disc immunosensor system was compared with a one step continuous flow injection immunoassay (FIIA) system, using the same reagents and a protein G column, in terms of assay sensitivity and influence of matrix effects from various water samples (millipore-, tap- and surface water). The detection limit for the analyte atrazine in PBS and surface water (SW) was 0.208±0.004 μg l−1 (PBS) and 0.59±0.120 μg l−1 (SW) for the FIIA and 0.033±0.003 μg l−1 (PBS) and 0.038±0.003 μg l−1 (SW) for the disc immunosensor. Statistical comparison of the two systems shows that the disc immunosensor results were significantly less influenced by the sample matrix, which is explained by the fact that the sample in the FIIA arrives simultaneously with the matrix to the detector, whereas these are separated in time in the disc immunosensor system.

Place, publisher, year, edition, pages
2004. Vol. 19, no 8, 795-803 p.
Keyword [en]
Atrazine, Chemiluminescence, Immunosensor, Monolith, Protein G, Solid phase reactor
URN: urn:nbn:se:umu:diva-14763DOI: doi:10.1016/j.bios.2003.08.008OAI: diva2:154435
Available from: 2008-04-17 Created: 2008-04-17 Last updated: 2011-01-12Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text
By organisation

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 24 hits
ReferencesLink to record
Permanent link

Direct link