Fit of implant frameworks: an in vitro comparison between two fabrication techniques.
Umeå University, Faculty of Medicine, Odontology.
2003 (English)In: The Journal of Prosthetic Dentistry, Vol. 89, no 3, 256-60 p.Article in journal (Refereed) Published
Abstract [en]

STATEMENT OF PROBLEM: It has been suggested that a precise fit between the implant and the framework cylinder is necessary to ensure a satisfactory long-term clinical outcome. PURPOSE: The purpose of this study was to compare the precision of fit between implant abutments and framework cylinders in frameworks fabricated by the Procera system and those fabricated from cast gold-alloy. MATERIAL AND METHODS: A total of 19 frameworks, 14 made with the Procera system (type 1) and 5 made of a cast gold-alloy (type 2), were fabricated. A total of 95 implants, 70 type 1 and 25 type 2 frameworks, were evaluated. Three replicas of the space between the implant abutments and the framework cylinders of the master cast were made for each test specimen. The replicas were cut with a scalpel in 2 axial directions: buccal-lingual and right-left. For the purpose of measurement, a microscope with a precision of +/- 0.5 microm was used at original magnification x30. The Student t test was used to determine whether there were significant differences between the framework designs. RESULTS: The buccal-lingual measurements for the type 1 and type 2 frameworks showed mean values of 28.1 microm (SD 9.8) and 42.0 microm (SD 1.8) on the buccal side, respectively, and 25.6 microm (SD 11.2) and 51.6 microm (SD 10.9) on the lingual side, respectively. For the right-left view, the mean measurements were 26.6 microm (SD 8.4) and 49.2 microm (SD 11.4) on the right side, respectively, and 27.4 microm (SD 8.5) and 44.4 microm (SD 6.5) on the left side, respectively. The total mean value for type 1 frameworks was 26.9 microm (SD 9.3); that for type 2 frameworks was 46.8 microm (SD 8.8). CONCLUSION: Within the limitations of this experiment, it was demonstrated that the fit of frameworks made with the Procera system was significantly better than that of the frameworks made with cast gold-alloy (P<.01).

Place, publisher, year, edition, pages
2003. Vol. 89, no 3, 256-60 p.
URN: urn:nbn:se:umu:diva-17656PubMedID: 12644800OAI: diva2:157329
Available from: 2007-11-15 Created: 2007-11-15 Last updated: 2011-01-13Bibliographically approved

Open Access in DiVA

No full text


Search in DiVA

By author/editor
Gunne, Johan
By organisation

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 38 hits
ReferencesLink to record
Permanent link

Direct link