Sputum eosinophils and the response of exercise-induced bronchoconstriction to corticosteroid in asthma.
Umeå University, Faculty of Medicine, Department of Public Health and Clinical Medicine, Pulmonary Medicine.
Show others and affiliations
2008 (English)In: Chest, ISSN 0012-3692, E-ISSN 1931-3543, Vol. 133, no 2, 404-11 p.Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: The relationship between eosinophilic airway inflammation and exercise-induced bronchoconstriction (EIB), and the response to inhaled corticosteroid (ICS) therapy was examined. METHODS: Twenty-six steroid-naïve asthmatic patients with EIB were randomized to two parallel, double-blind, crossover study arms (13 subjects in each arm). Each arm compared two dose levels of inhaled ciclesonide that were administered for 3 weeks with a washout period of 3 to 8 weeks, as follows: (1) 40 vs 160 microg daily; and (2) 80 vs 320 microg daily. Baseline and weekly assessments with exercise challenge and sputum analysis were performed. RESULTS: Data were pooled and demonstrated that 10 subjects had baseline sputum eosinophilia >or= 5%. Only high-dose ICS therapy (ie, 160 and 320 microg) significantly attenuated the sputum eosinophil percentage. Sputum eosinophil percentage significantly correlated with EIB severity, and predicted the magnitude and temporal response of EIB to high-dose therapy, but not to low-dose therapy (ie, 40 and 80 microg). Low-dose ICS therapy provided a significant reduction in EIB at 1 week, with little additional improvement thereafter, irrespective of baseline sputum eosinophil counts. In contrast, high-dose ICS therapy provided a significantly greater improvement in EIB in subjects with sputum eosinophilia compared to those with an eosinophil count of < 5%. The difference between the eosinophilic groups in the magnitude of improvement in EIB was evident after the first week of high-dose ICS therapy and increased with time. CONCLUSIONS: These results suggest that eosinophilic airway inflammation may be important in modifying the severity of EIB and the response to ICS therapy. Measurements of sputum eosinophil percentage may, therefore, be useful in predicting the magnitude and temporal response of EIB to different dose levels of ICSs. Trial registration:; Identifier: NCT00525772.

Place, publisher, year, edition, pages
2008. Vol. 133, no 2, 404-11 p.
URN: urn:nbn:se:umu:diva-21058DOI: 10.1378/chest.07-2048PubMedID: 18071011OAI: diva2:210551
Available from: 2009-04-02 Created: 2009-04-02 Last updated: 2011-08-24

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Adelroth, Ellinor
By organisation
Pulmonary Medicine
In the same journal

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 45 hits
ReferencesLink to record
Permanent link

Direct link