Change search
ReferencesLink to record
Permanent link

Direct link
Cemented versus uncemented fixation of the femoral component of the NexGeb CR total knee replacement in patients younger than 60 years: A Prospective Randomised Controlled RSA Study
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Orthopaedics.
Falu General Hospital, Falun, Sweden.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Orthopaedics.ORCID iD: 0000-0002-8818-3408
2009 (English)In: The Knee, ISSN 0968-0160, Vol. 16, no 3, 200-206 p.Article in journal (Refereed) Published
Abstract [en]

The optimal mode of femoral fixation in total knee arthroplasty (TKA) remains controversial, especially for the young patient. In a prospective randomised study we compared the magnitude and pattern of the fixation of cemented versus uncemented femoral components during 2 years in patients younger than 60 years. Forty-one knees in 41 patients were randomised to receive a NexGen (Zimmer, Warsaw, USA) cruciate-retaining TKA with either a cemented or an uncemented non HA-coated femoral component. The patients were examined by radiostereometric analysis (RSA), as well as clinical and radiological evaluation. The magnitude and pattern of migration as measured by RSA did not differ significantly between the cemented and uncemented fixation during the 2-year follow-up, nor were there any differences between the groups in clinical parameters. These findings suggest that an uncemented and non HA-coated femoral component may behave equally as well as a cemented one in the long-term.

Place, publisher, year, edition, pages
2009. Vol. 16, no 3, 200-206 p.
National Category
URN: urn:nbn:se:umu:diva-23502DOI: 10.1016/j.knee.2008.11.009OAI: diva2:224800
Available from: 2009-06-22 Created: 2009-06-22 Last updated: 2016-02-09Bibliographically approved
In thesis
1. Total knee arthroplasty: aspects on improved fixation in the younger patient
Open this publication in new window or tab >>Total knee arthroplasty: aspects on improved fixation in the younger patient
2008 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The results of total knee arthroplasty are inferior in younger patients. The challenge today is therefore to develop designs and concepts that will last at least 25 years.

This thesis has evaluated the fixation to bone of modern designs of knee prostheses uring RSA analysis. Coating implant surfaces with hydroxy-apatite have proven to enhance fixation to bone. Addition of screws for fixation of the tibial component enhances the fixation, but has negative side effects such as osteolysis around the screws, in turn leading to a higher risk of component loosening. The magnitude and pattern of migration was studied in a randomized study of uncemented tibial implants coated with hydroxy-apatite with and without additional screw fixation in patients younger than 65 years. The uncemented implants migrated initially more than the cemented implants that constituted the control group. Both uncemented groups stabilized at 3 monthes with no further migration, while the cemented implants showed a continuous migration up to the 2 year follow-up, indicating continuous bone resorption at the implant-bone interface, a fact that might lead to an increased risk of late implant loosening. This may not be a problem in older patients, but may have consequences for long-term fixation in younger patients. There was no difference between the two uncemented groups indicating that screws do not improve fixation. Hydroxy-apatite coated knee implants might be well suited for younger patients.

Mobile bearing total knee arthroplasty theoretically uncouples the forces at the implant-bone interface, thus improving fixation of the implant to bone. The magnitude and pattern of migration of a cemented mobile bearing knee arthroplasty and a fixed bearing total knee arthroplasty was compared in a randomized study. The results showed that mobile bearings did not improve fixation.

Trabecular metal, a new material recently introduced for total knee arthroplasty, has several theoretical advantages. Trabecular metal tibial implants were evaluated in a randomized study in patients younger than 60 years. The implants displayed the typical migration pattern for uncemented implants with greater migration initially followed by early stabilization. The majority of the trabecular metal implants subsided into the bone with no lift-off. Lift-off has the potential of exposing the interface to joint fluid with the potential risk of bone resorption and late loosening, and is commonly seen in metal-backed implants. The finding of absence of lift-off is regarded beneficial for uncemented fixation. Trabecular metal tibial implants might be suited for younger patients.

The optimal mode of fixation of the femoral component is yet to be established. Comparing cemented femoral components with uncemented femoral components in a randomized study in patients younger than 60 years revealed no differences of the magnitude or the pattern of migration. Uncemented femoral component seems equally as good as cemented components in younger patients.

Place, publisher, year, edition, pages
Umeå: Ortopedi, 2008. 73 p.
Umeå University medical dissertations, ISSN 0346-6612 ; 1172
Surgery, Total knee arthroplasty, total knee replacement, mobile bearing, trabecular metal, hydroxy-apatite coating, Kirurgi
Research subject
urn:nbn:se:umu:diva-1648 (URN)978-91-7264-549-3 (ISBN)
Public defence
2008-05-30, Föreläsningssalen, Falu lasarett, Falun, 09:00 (English)
Available from: 2008-05-13 Created: 2008-05-13 Last updated: 2010-01-21Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Gao, FengNilsson, Kjell G
By organisation

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 59 hits
ReferencesLink to record
Permanent link

Direct link