Change search
ReferencesLink to record
Permanent link

Direct link
Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years.
Department of Orthopaedics, Ullevål University Hospital, Division of Neuroscience, Orthopaedics and Rehabilitation, Oslo, Norway.
Perth Orthopaedic Institute, University of Western Australia, Perth, Australia.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Orthopaedics.
Perth Orthopaedic Institute, University of Western Australia, Perth, Australia.
2007 (English)In: Acta Orthopaedica, ISSN 1745-3674, E-ISSN 1745-3682, Vol. 78, no 6, 739-745 p.Article in journal (Refereed) Published
Abstract [en]

Background and purpose: Highly cross-linked polyethylenes (PEs) all appear to reduce wear dramatically in laboratory studies, although there is substantial variation in this respect between manufacturers. Nonremelted cross-linked PE is almost as tough as unirradiated PE, but is not completely stable and can oxidize in vivo, as has been shown in recent retrievals studies.

We had reported low wear and good clinical performance after 2 years for 10 non-remelted highly crosslinked PE cups compared to 16 conventional PE cups sterilized by gamma-in-air.

Method: Because of possible degradation by free radicals, we followed up both cohorts for 5 years (conventional PE) and 6 years (highly cross-linked PE).

Result: Mean (CI) proximal head penetration over the observation time was linear and measured 0.08 (0.02–0.13) mm for cross-linked PE and 0.42 (0.23–0.62) mm for conventional PE, and total penetration was 0.23 (0.1–0.35) mm and 0.75 (0.05–1.4) mm respectively. After subtracting creep, the annual wear for non-remelted highly cross-linked PE was below 6 µm. The cups had equally low migration and few radiolucencies.

Interpretation: The theoretical possibility of oxidation in non-remelted highly cross-linked PE may not show clinically. However, it may be that cemented cups with their thicker PE are more forgiving than metal-backed cups with thin PE moving in the locking mechanism. So far, we can conclude that the Crossfire highly crosslinked polyethylene cups performed very well clinically, with extremely low wear even after almost 6 years. This is reassuring, but care should be taken in extrapolating these results to other cross-linked PEs or uncemented cups where toughness of PE is more of an issue.

Place, publisher, year, edition, pages
Basingstoke: Taylor & Francis , 2007. Vol. 78, no 6, 739-745 p.
URN: urn:nbn:se:umu:diva-24477DOI: 10.1080/17453670710014509OAI: diva2:226502
Available from: 2009-06-30 Created: 2009-06-30 Last updated: 2011-04-13Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text
By organisation
In the same journal
Acta Orthopaedica

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 30 hits
ReferencesLink to record
Permanent link

Direct link