Semi-conductor detectors in output factor measurements
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
1997 (English)In: Radiotherapy and Oncology, ISSN 0167-8140, E-ISSN 1879-0887, Vol. 42, no 3, 293-296 p.Article in journal (Refereed) Published
Abstract [en]

Background and purpose: Output factors are generally measured with cylindrical ionization chambers. It was investigated if Si-diodes of p-type instead could be used. The advantage would be the small detector size and the robust construction of the detector.

Materials and methods: Two types of diodes were studied, one with a shielding layer of tungsten specially made to reduce the excess response for scattered photons and one standard diode without any extra shielding. The measurements were performed at accelerating potentials between 4 and 50 MV and beam sizes between 4 cm x 4 cm and 40 cm x 40 cm.

Results: The results showed that both types of diodes are suitable for measurements of head scatter factors in mini-phantoms. However, the diodes were found inappropriate for measurement of output factors for large fields in extended water phantoms. For small fields (<10 cm x 10 cm) a small detector is advantageous and no errors due to the scatter contribution were seen.

Conclusions: An cylindrical ionization chamber is the best choice for output factor measurements in extended water phantoms for large field sizes while diodes are an alternative in small fields. There were negligible differences between the detectors in head scatter measurements in mini phantoms.

Place, publisher, year, edition, pages
1997. Vol. 42, no 3, 293-296 p.
Keyword [en]
Photons; Head scatter factor; Mini phantom; Output factor; Diode
Identifiers
URN: urn:nbn:se:umu:diva-39954DOI: 10.1016/S0167-8140(97)01917-8ISI: A1997WW83000014OAI: oai:DiVA.org:umu-39954DiVA: diva2:396919
Available from: 2011-02-11 Created: 2011-02-11 Last updated: 2017-12-11Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Karlsson, Magnus GKarlsson, MikaelSjögren, RickardSvensson, Hans
By organisation
Radiation Physics
In the same journal
Radiotherapy and Oncology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 143 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf