Radiation doses in examination of lower third molars with computed tomography and conventional radiography.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
2008 (English)In: Dento-Maxillo-Facial Radiology, ISSN 0250-832X, Vol. 37, no 8, 445-452 p.Article in journal (Refereed) Published
Abstract [en]

OBJECTIVES: To measure organ doses and calculate effective doses for pre-operative radiographic examination of lower third molars with CT and conventional radiography (CR).

METHODS: Measurements of organ doses were made on an anthropomorphic head phantom with lithium fluoride thermoluminescent dosemeters. The dosemeters were placed in regions corresponding to parotid and submandibular glands, mandibular bone, thyroid gland, skin, eye lenses and brain. The organ doses were used for the calculation of effective doses according to proposed International Commission on Radiological Protection 2005 guidelines. For the CT examination, a Siemens Somatom Plus 4 Volume Zoom was used and exposure factors were set to 120 kV and 100 mAs. For conventional radiographs, a Scanora unit was used and panoramic, posteroanterior, stereographic (scanogram) and conventional spiral tomographic views were exposed.

RESULTS: The effective doses were 0.25 mSv, 0.060 mSv and 0.093 mSv for CT, CR without conventional tomography and CR with conventional spiral tomography, respectively.

CONCLUSIONS: The effective dose is low when CT examination with exposure factors optimized for the examination of bone structures is performed. However, the dose is still about four times as high as for CR without tomography. CT should therefore not be a standard method for the examination of lower third molars. In cases where there is a close relationship between the tooth and the inferior alveolar nerve the advantages of true sectional imaging, such as CT, outweighs the higher effective dose and is recommended. Further reduction in the dose is feasible with further optimization of examination protocols and the development of newer techniques.

Place, publisher, year, edition, pages
2008. Vol. 37, no 8, 445-452 p.
Keyword [en]
thermoluminescent dosimetry, third molar, computed tomography, dental radiography
URN: urn:nbn:se:umu:diva-50297DOI: 10.1259/dmfr/86360042PubMedID: 19033429OAI: diva2:461659
Available from: 2011-12-05 Created: 2011-12-05 Last updated: 2011-12-05

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Andersson, Jonas
By organisation
Radiation Physics
In the same journal
Dento-Maxillo-Facial Radiology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 195 hits
ReferencesLink to record
Permanent link

Direct link