Change search
ReferencesLink to record
Permanent link

Direct link
Automatic filtering of outliers in RR intervals before analysis of heart rate variability in Holter recordings: a comparison with carefully edited data.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Clinical Physiology.
Umeå University, Faculty of Medicine, Department of Clinical Sciences, Paediatrics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
2012 (English)In: Biomedical engineering online, ISSN 1475-925X, Vol. 11, no 2, 12- p.Article in journal (Refereed) Published
Abstract [en]

Background: Undetected arrhythmic beats seriously affect the power spectrum of the heart rate variability (HRV). Therefore, the series of RR intervals are normally carefully edited before HRV is analysed, but this is a time consuming procedure when 24-hours recordings are analysed. Alternatively, different methods can be used for automatic removal of arrhythmic beats and artefacts. This study compared common frequency domain indices of HRV when determined from manually edited and automatically filtered RR intervals.

Methods and Results: Twenty-four hours Holter recordings were available from 140 healthy subjects of age 1-75 years. An experienced technician carefully edited all recordings. Automatic filtering was performed using a recursive procedure where RR intervals were removed if they differed from the mean of the surrounding RR intervals with more than a predetermined limit (ranging from 10% to 50%). The filtering algorithm was evaluated by replacing 1% of the beats with synthesised ectopic beats. Power spectral analysis was performed before and after filtering of both the original edited data and the noisy data set. The results from the analysis using the noisy data were used to define an age-based filtering threshold. The age-based filtration was evaluated with completely unedited data, generated by removing all annotations from the series of RR intervals, and then comparing the resulting HRV indices with those obtained using edited data. The results showed equivalent results after age-based filtration of both the edited and unedited data sets, where the differences in HRV indices obtained by different preprocessing methods were small compared to the mean values within each age group.

Conclusions: The study showed that it might not be necessary to perform the time-consuming careful editing of all detected heartbeats before HRV is analysed in Holter recordings.

In most subjects, it is sufficient to perform the regular editing needed for valid arrhythmia analyses, and then remove undetected ectopic beats and artefacts by age-based filtration of the series of RR intervals, particularly in subjects older than 30 years.

Place, publisher, year, edition, pages
2012. Vol. 11, no 2, 12- p.
National Category
Biomedical Laboratory Science/Technology
URN: urn:nbn:se:umu:diva-51790DOI: 10.1186/1475-925X-11-2PubMedID: 22236441OAI: diva2:488687
Available from: 2012-02-02 Created: 2012-02-02 Last updated: 2012-02-28Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Karlsson, MarcusHörnsten, RolfRydberg, AnnikaWiklund, Urban
By organisation
Radiation PhysicsClinical PhysiologyPaediatrics
In the same journal
Biomedical engineering online
Biomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 58 hits
ReferencesLink to record
Permanent link

Direct link