umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Imaging of parastomal hernia using three-dimensional intrastomal ultrasonography
Department of Surgery, CLINTEC, Karolinska Institute at the Karolinska University Hospital, Huddinge, Stockholm, Sweden.
Department of Surgery, CLINTEC, Karolinska Institute at the Karolinska University Hospital, Huddinge, Stockholm, Sweden.
Department of Surgery, CLINTEC, Karolinska Institute at the Karolinska University Hospital, Huddinge, Stockholm, Sweden.
2011 (Engelska)Ingår i: British Journal of Surgery, ISSN 0007-1323, E-ISSN 1365-2168, Vol. 98, nr 7, s. 1026-9Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

BACKGROUND: Parastomal hernia is common in patients with a permanent stoma. At present there is no standard method for imaging a parastomal hernia. The aim of this study was to investigate the value of three-dimensional intrastomal ultrasonography in differentiating between a parastomal hernia and a bulge.

METHODS: Twenty patients were divided into four groups according to ultrasonography setting and probe cover. All patients were tested using three different ultrasound probe frequencies (9, 13 and 16 MHz). The intrastomal examination was performed during provocation in both the supine and upright positions, with a protector or water-containing balloon surrounding the probe.

RESULTS: The sharpest images were obtained using the rectal setting with a water-containing balloon surrounding the probe at 9 MHz in supine and erect positions, for evaluation of both fascia and muscle; in some instances even implanted mesh was detectable. When switched to render mode, the pictures improved in sharpness and it was easier to identify anatomical landmarks.

CONCLUSION: Intrastomal ultrasonography using the rectal setting and a frequency of 9 MHz is a feasible method for imaging a parastomal hernia and differentiating it from an abdominal bulge. The image quality improves when render mode is used.

Ort, förlag, år, upplaga, sidor
2011. Vol. 98, nr 7, s. 1026-9
Nationell ämneskategori
Kirurgi
Identifikatorer
URN: urn:nbn:se:umu:diva-57253DOI: 10.1002/bjs.7505PubMedID: 21509751OAI: oai:DiVA.org:umu-57253DiVA, id: diva2:540575
Tillgänglig från: 2012-07-10 Skapad: 2012-07-10 Senast uppdaterad: 2018-06-08

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Gunnarsson, UlfStrigård, Karin

Sök vidare i DiVA

Av författaren/redaktören
Gunnarsson, UlfStrigård, Karin
I samma tidskrift
British Journal of Surgery
Kirurgi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 119 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf