umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Assessment of abdominal muscle function using the Biodex System-4. Validity and reliability in healthy volunteers and patients with giant ventral hernia
Department of Surgery, CLINTEC, Karolinska Institutet, Karolinska University Hospital, Gastrocentrum K53, 141 86, Huddinge, Stockholm, Sweden .
Department of Physiotherapy, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, Sweden .
Department of Surgery, CLINTEC, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden.
2011 (Engelska)Ingår i: Hernia, ISSN 1265-4906, E-ISSN 1248-9204, Vol. 15, nr 4, s. 417-421Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

BACKGROUND: The decrease in recurrence rates in ventral hernia surgery have led to a redirection of focus towards other important patient-related endpoints. One such endpoint is abdominal wall function. The aim of the present study was to evaluate the reliability and external validity of abdominal wall strength measurement using the Biodex System-4 with a back abdomen unit.

MATERIAL AND METHOD: Ten healthy volunteers and ten patients with ventral hernias exceeding 10 cm were recruited. Test-retest reliability, both with and without girdle, was evaluated by comparison of measurements at two test occasions 1 week apart. Reliability was calculated by the interclass correlation coefficients (ICC) method. Validity was evaluated by correlation with the well-established International Physical Activity Questionnaire (IPAQ) and a self-assessment of abdominal wall strength.

RESULTS: One person in the healthy group was excluded after the first test due to neck problems following minor trauma. The reliability was excellent (>0.75), with ICC values between 0.92 and 0.97 for the different modalities tested. No differences were seen between testing with and without a girdle. Validity was also excellent both when calculated as correlation to self-assessment of abdominal wall strength, and to IPAQ, giving Kendall tau values of 0.51 and 0.47, respectively, and corresponding P values of 0.002 and 0.004.

CONCLUSION: Measurement of abdominal muscle function using the Biodex System-4 is a reliable and valid method to assess this important patient-related endpoint. Further investigations will be made to explore the potential of this technique in the evaluation of the results of ventral hernia surgery, and to compare muscle function after different abdominal wall reconstruction techniques.

Ort, förlag, år, upplaga, sidor
Paris: Springer, 2011. Vol. 15, nr 4, s. 417-421
Nyckelord [en]
Giant ventral hernia, Abdominal muscle strength, Biodex System-4, Girdle
Nationell ämneskategori
Kirurgi
Identifikatorer
URN: urn:nbn:se:umu:diva-57255DOI: 10.1007/s10029-011-0805-1PubMedID: 21380564OAI: oai:DiVA.org:umu-57255DiVA, id: diva2:540578
Tillgänglig från: 2012-07-10 Skapad: 2012-07-10 Senast uppdaterad: 2018-06-08

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Gunnarsson, UlfStrigård, Karin

Sök vidare i DiVA

Av författaren/redaktören
Gunnarsson, UlfStrigård, Karin
I samma tidskrift
Hernia
Kirurgi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 138 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf