Comparison of blood pressure measurements between an automated oscillometric device and a Hawksley random-zero sphygmomanometer in the northern Sweden MONICA study.
Umeå universitet, Samhällsvetenskapliga fakulteten, Handelshögskolan vid Umeå universitet, Statistik.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
2012 (Engelska)Ingår i: Blood Pressure Monitoring, ISSN 1359-5237, E-ISSN 1473-5725, Vol. 17, nr 4, s. 164-170Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

BACKGROUND: The Hawksley random-zero sphygmomanometer (random-zero) has been used widely in epidemiological observation studies. This study compares blood pressure measurements using the random-zero with measurements using an automated oscillometric device and suggests a correction of the automated oscillometric measurements to enable comparisons of blood pressure levels over time.

METHODS: The northern Sweden MONICA population survey 2009 included 1729 participants, 853 men and 876 women, 25-74 years old. Blood pressure was measured using both random-zero and an automated oscillometric device in all participants. The Omron M7 digital blood pressure monitor was used for automated oscillometric measurements. A linear mixed model was used to derive a formula to adjust the automated oscillometric readings.

RESULTS: Automated oscillometric measurements of systolic blood pressure were generally lower than random-zero measurements in women [oscillometric mean 122.1 mmHg (95% confidence interval: 121.0-123.2) versus random-zero mean 124.4 mmHg (123.5-125.5)], whereas automated oscillometric measurements of systolic blood pressure were generally higher than random-zero measurements in men [oscillometric 131.1 mmHg (130.0-132.2) versus random-zero 129.0 mmHg (127.9-130.1)]. For diastolic blood pressure, automated oscillometric measurements were higher in both women [oscillometric 79.9 mmHg (79.2-80.5) versus random-zero 76.7 mmHg (76.0-77.4)] and men [oscillometric 83.1 mmHg (82.4-83.8) vs. random-zero 81.2 mmHg (80.6-81.9)]. The difference also varied with age and order of measurement. Adjustment of the automated oscillometric measurements using mixed model regression coefficients produced estimates of blood pressure that were close to the random-zero measurements.

CONCLUSION: Blood pressure measurements using an automated oscillometric device differ from those with random-zero, but the oscillometric measurements can be adjusted, on the basis of sex, age and measurement order, to be similar to the random-zero measurements.

Ort, förlag, år, upplaga, sidor
2012. Vol. 17, nr 4, s. 164-170
Nyckelord [en]
blood pressure; blood pressure measurement; blood pressure monitoring; Omron; oscillometric; random-zero
Nationell ämneskategori
Folkhälsovetenskap, global hälsa, socialmedicin och epidemiologi
Identifikatorer
URN: urn:nbn:se:umu:diva-57497DOI: 10.1097/MBP.0b013e328356ef58PubMedID: 22781634OAI: oai:DiVA.org:umu-57497DiVA, id: diva2:542913
Tillgänglig från: 2012-08-06 Skapad: 2012-08-06 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Eriksson, MarieCarlberg, BoJansson, Jan-Håkan

Sök vidare i DiVA

Av författaren/redaktören
Eriksson, MarieCarlberg, BoJansson, Jan-Håkan
Av organisationen
StatistikMedicin
I samma tidskrift
Blood Pressure Monitoring
Folkhälsovetenskap, global hälsa, socialmedicin och epidemiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 218 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf