umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Three-day CSF drainage barely reduces ventricular size in normal pressure hydrocephalus
Umeå University, Faculty of Medicine, Department of Pharmacology and Clinical Neuroscience, Clinical Neuroscience.
Umeå University, Faculty of Medicine, Department of Pharmacology and Clinical Neuroscience, Clinical Neuroscience.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Diagnostic Radiology.
Show others and affiliations
2012 (English)In: Neurology, ISSN 0028-3878, E-ISSN 1526-632X, Vol. 79, no 3, 237-242 p.Article in journal (Refereed) Published
Abstract [en]

Objective: External lumbar drainage (ELD) of CSF is a test to determine the suitability of a shunt for patients with normal pressure hydrocephalus (NPH), but its effect on ventricular volume is not known. This study investigates the effect of 3-day ELD of 500 mL on ventricular size and clinical features in patients with idiopathic NPH.

Methods: Fifteen patients were investigated in a 1.5-T MRI scanner before and after ELD. Ventricular volume was measured manually. Clinical features involved motor and cognitive functions, testing primarily gait and attention. Reduction in ventricular volume was correlated to total drain volume and clinical parameters. Statistical tests were nonparametric, and p < 0.05 was required for significance.

Results: Drain volume was 415 mL (median 470 mL, range 160-510 mL). Ventricular size was reduced in all patients, averaging 3.7 mL (SD 2.2 mL, p < 0.001), which corresponded to a 4.2% contraction. The ratio of volume contraction to drain volume was only 0.9%. Seven patients improved in gait and 6 in attention. Ventricular reduction and total drain volume correlated neither with improvement nor with each other. The 7 patients with the largest drain volumes (close to 500 mL), had ventricular changes varying from 1.3 to 7.5 mL.

Conclusions: Clinical improvement occurs in patients with NPH after ELD despite unaltered ventricles, suggesting that ventricular size is of little relevance for postshunt improvement or determining shunt function. The clinical effect provided by ELD, mimicking shunting, is probably related to the recurring CSF extractions rather than to the cumulative effect of the drainage on ventricular volume. Neurology(R) 2012;79:237-242

Place, publisher, year, edition, pages
Philadelphia: Lippincott Williams & Wilkins, 2012. Vol. 79, no 3, 237-242 p.
National Category
Neurosciences Neurology
Identifiers
URN: urn:nbn:se:umu:diva-57824DOI: 10.1212/WNL.0b013e31825fdf8aISI: 000306468100012OAI: oai:DiVA.org:umu-57824DiVA: diva2:545042
Available from: 2012-08-17 Created: 2012-08-16 Last updated: 2017-12-07Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Lenfeldt, NiklasHansson, WilliamLarsson, AnneBirgander, RichardEklund, AndersMalm, Jan
By organisation
Clinical NeuroscienceRadiation PhysicsDiagnostic Radiology
In the same journal
Neurology
NeurosciencesNeurology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 92 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf