umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Passivhus: Checklistor till byggherren, projektörerna, entreprenörerna och brukarna
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2011 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Passive house : Checklists to the owner of the buildning project, the designers, the contractors and the users (English)
Abstract [sv]

Ett passivt hus är en typ av lågenergihus, där isoleringen är tjockare, fönstren har bättre Uvärde och konstruktionen är helt tät. Hur mycket tjockare isolering och hur bättre U-värde som behövs beror på byggnadens placering, utformning samt vilket klimat det är. Denna hustyp gör att man kan minska sitt effektbehov. I ett passivt hus i Sverige får man endast använda 10 W/m 2 i söder och 12 W/m2 i norr. Man använder även energisnåla apparater för att reducera energianvändningen. Passivhus är ett boende med låga energikostnader, hög kvalitet och bra komfort.

Syftet med mitt examensarbete är att ta fram vad ingenjören och de andra aktörerna i processen behöver ha för information för att kunna fullfölja deras projekt. Det jag fick fram var checklistor med manualer som ger en förklaring, listorna och manualerna är indelade till de olika aktörerna.

Abstract [en]

A passive house is a type of low-energy house, where the isolation is thicker, the windows have a better U-value and the construction is completely sealed. How much thicker the isolation needs to be and how better U-value that is required depends on the building's location, design, and what kind of climate it is. This type of building makes it possible to reduce the power demand. In south of Sweden, passive houses are only allowed to use 10 W/m 2. But in north of Sweden, passive houses are allowed to use 12 W/m2. It also uses energy-efficient appliances to reduce the energy use. Passive House is a house with low energy costs, high quality and good comfort.

The purpose of my project is to develop what the engineer and the other actors need to know in the process so they can complete their project. What I came up with was some check lists and a manual that gives the explanation, these check lists and the manual are divided into the different actors.

Place, publisher, year, edition, pages
2011. , 35 p.
Series
BY, 1117
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:umu:diva-58246OAI: oai:DiVA.org:umu-58246DiVA: diva2:547493
External cooperation
Umeå kommun
Educational program
Bachelor of Science Programme in Civil Engineering
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-08-29 Created: 2012-08-28 Last updated: 2012-08-29Bibliographically approved

Open Access in DiVA

No full text

By organisation
Department of Applied Physics and Electronics
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 81 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf