Lufttäthetens inverkan på energiberäkningar för byggnader
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2012 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
Impacts of airtightness on energy calculations for buildings (English)
Abstract [sv]

I och med höjda energipriser och ökad medvetenhet om naturresursernas ändlighet har intresset för energieffektivisering ökat inom alla områden. I ett av riksdagens miljökvalitetsmål anges att energianvändningen i bostäder och lokaler bör minska med 20 % till år 2020 i förhållande till den användning som var 1995. Som det ser ut idag har energianvändningen i bostäder och lokaler snarare ökat än minskat sedan 1995 därför krävs stora krafttag om målet ska nås.

De största värmeförlusterna i en byggnad sker genom transmissionsförluster. En annan förlustfaktor i en byggnad är det okontrollerade luftflödet som transporteras in eller ut ur klimatskalet genom springor och otätheter i konstruktionen. Detta luftläckage är svårt att uppskatta eller beräkna utan att göra en täthetsmätning av byggnaden. Täthetsmätningar är tidskrävande vilket gör att det finns ett stort behov av att kunna uppskatta ett värde för att använda i energiberäkningar för byggnader. Syftet med detta projekt är att ta fram bättre riktlinjer för val av indata och att undersöka hur en byggnads lufttäthet kan uppskattas med avseende på energiberäkningar. Detta projekt är uppdelat i tre delar; litteraturstudie, fallstudie av en byggnad där luftläckaget mäts och uppmätt energiförbrukning jämförs med beräknad samt en känslighetsanalys och en jämförelse mellan beräkningsprogrammen RIUSKA och IDA ICE.

Resultatet från känslighetsanalyserna visar att läckaget har större påverkan på det beräknade uppvärmningsbehovet i RIUSKA än i IDA ICE. Det beräknade uppvärmningsbehovet kan öka med upp till 30 % i RIUSKA av att ta med luftläckaget. Det är endast vid användning av programmet IDA ICE som det finns möjlighet att ta med köldbryggor beräkningarna. Köldbryggorna kan öka det beräknade uppvärmningsbehovet med upp till 30 %. Detta är en så betydande påverkan att köldbryggor borde tas med i beräkningarna. Luftläckaget för byggnader borde enligt de mätdata som studerats ligga mellan 0,2-1,5 l/s, m2 omslutande area eller 0,2-2,3 oms/h vid 50 Pa tryckdifferens. Att koppla storleken på luftläckaget till olika byggnadstyper är mycket svårt om inte till och med omöjligt. Enligt flera ingenjörer som tillfrågats beror storleken på luftläckaget i en byggnad snarare av noggrannhet vid byggnation än typ av konstruktion. En annan allmän uppfattning är att betongkonstruktioner är lättare att få täta än träkonstruktioner.

Fler lufttäthetsmätningar skulle tillsammans med uppföljningar av gjorda energiberäkningar ge en bättre bild av hur bra dagens energiberäkningar är och hur luftläckaget i olika byggnader ser ut.

Abstract [en]

With the rising energy prices and the increased awareness about our natural recourses the interest in energy efficiency in all areas has increased. One of the Swedish parliament’s environmental quality objectives states that energy consumption in residential and commercial buildings should be reduced by 20 % until 2020 compared to the consumption in 1995. Until today the consumption has rather increased than decreased, therefore an extensive reform is needed to reach the goal.

Transmission is the most important factor in heat loss of buildings. Another loss factor is the unregulated flow of air through cracks in the building envelope. The air leakage is difficult to determine without a measurement of the building air tightness. Since this measurement is time consuming it would be a good thing to be able to estimate the leakage for energy calculations of buildings. The purpose of this project is to develop guidelines for how to choose input data for energy calculations. To find out how to determine or estimate the air leakage for use in energy calculations is also a part of the purpose. The project is divided in three parts; a literature study, a case study of a building where measured and calculated air leakage is compared and where an air tightness measurement is conducted and sensitivity analysis and comparison of two computer calculation programs, RIUSKA and IDA ICE.

The results of the sensitivity analysis show that the air leakage plays a larger role in calculations in RIUSKA than in IDA ICE. The calculated heat consumption can increase by up to 30 % in RIUSKA when including air leakage. Thermal bridges can only be taken into account in calculations in IDA ICE and the sensitivity analysis show that thermal bridges has a significant impact on the calculated heat demand, up to 30 %. The air leakage in buildings should, if looking at the studied leakage data, normally be between 0,2 and 2,3 1/h or 0,2-1,5 l/s, m2 Aenv at 50 Pa pressure difference. To link the size of air leakage with type of construction is very hard, it might even be impossible. Some people think that the air leakage is more linked with how the building is built than what type of construction it is. But it seems to be a common view that concrete buildings have higher air tightness than wood constructions.

More measurements and follow-ups of energy calculations would give a clearer picture of how realistic the present energy calculations are and how large the air leakage of different buildings is.

Place, publisher, year, edition, pages
2012. , 102 p.
Series
EN12
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:umu:diva-59071OAI: oai:DiVA.org:umu-59071DiVA: diva2:550800
External cooperation
Sweco Systems
Educational program
Master of Science Programme in Energy Engineering
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-09-07 Created: 2012-09-07 Last updated: 2012-09-07Bibliographically approved

Open Access in DiVA

fulltext(7330 kB)3254 downloads
File information
File name FULLTEXT01.pdfFile size 7330 kBChecksum SHA-512
067acd433c46290f0535317b23fc08f68a99b1786f07925c88aae7517843127532d020c9bf919dc2f67614530320454c91e654c3f0c3b6599ed20bc4ed2877ce
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 3254 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 341 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf