Analys av fördelningssystem för bostadshus
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2012 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

The purpose of this project is to analyze earthing systems for houses. By practical measurements and theoretical analyzes consequences of possible faults, that can occur within the facility and in the low-voltage distribution network, is illustrated.  

The reason for this project is that nowadays one has to arrange with a main equipotential bonding system for buildings. Apart from that, if necessary, bathrooms must be provided with a supplementary equipotential bonding system.

The practical measurements verify that potential differences in facilities may be due to voltage drops in the PEN conductor between the origin of the electrical installation and the power transformer.

Based on the theoretical analyzes of possible faults, it is considered that the requirement for  supplementary equipotential bonding systems for bathrooms in most cases can be questioned, when basic insulation, fault protection, residual current devise and main equipotential bonding system already provides an adequate level of protection.

A PEN conductor loss may result in a situation where metallic parts attached to the equipotential bonding system starts working as earth electrodes. Equipotential bonding system may also increase the incidence of stray currents. If TN-C-S systems is provided with a local connection to earth a redundant system against PEN conductor loss is obtained. That is not the case for neutral conductor loss in TN-S systems with a local connection to earth. If district heating pipes is supplied with insulated flanges it prevents stray currents and foreign potential to be spread in the district heating network.

Place, publisher, year, edition, pages
2012.
Keyword [sv]
Fördelningssystem, Potentialutjämning
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:umu:diva-60023OAI: oai:DiVA.org:umu-60023DiVA: diva2:557447
External cooperation
Tyréns AB
Educational program
Bachelor of Science Programme in Energy Engineering
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-10-05 Created: 2012-09-27 Last updated: 2012-10-05Bibliographically approved

Open Access in DiVA

Analys av fördelningssystem för bostadshus(1989 kB)1541 downloads
File information
File name FULLTEXT01.pdfFile size 1989 kBChecksum SHA-512
4144a519b949605a87129967ebcf5cf5591b5aacd69b5823ded7969f2c1e5ee9734ed657c88b70bd22f06054e12485b973566c4dd3d9ab3960df1090515e645d
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1541 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 137 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf