Energieffektivisering genom behovsstyrning av inomhusklimat
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2012 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Energy efficiency by controlling the indoor climate (English)
Abstract [sv]

Detta arbete handlar om ett energieffektivisering projekt på en biograf i Umeå genom att behovsstyra inomhusklimatet och på så vis sänka energiförbrukningen för värme- och ventilationssystemen men samtidigt lyckas upprätthålla en god inomhusmiljö för brukarna samt att gällande regler och lagstiftning inte bryts. Energieffektiviseringen är utförd av Schneider Electronic på en av Norrportens fastigheter.

Studier av diverse lagar och regelsamlingar, bland annat Boverkets Byggregler (BBR) och Socialstyrelsens allmänna råd, gjordes för att få reda på hur man får styra värme- och ventilationssystemen så att inomhusklimatet fortfarande kan hålla den kvalitet som krävs.

För att veta hur man ska styra inomhusklimatet på biografen behövdes information om hur förutsättningarna för värme- och ventilationssystemen såg ut. Detta undersöktes med hjälp av studiebesök, intervjuer samt litteraturstudier. Det visade sig vara ett system där tilluften värmdes eller kyldes av ett värme- respektive kylbatteri innan den skickades ut i lokalerna. Energin till uppvärmningen kom från fjärrvärme medan kylan drevs med hjälp av el. Några radiatorer fanns i korridorerna samt under fönstren i foajén och i biosalongerna fanns luftvärmare som kunde användas vid behov.

Själva energieffektiviseringsprojektet gick ut på att värme- och ventilationssystemen inte skulle jobba lika hårt men framförallt så skulle de vara igång färre timmar under dygnet. Detta skulle lösas genom installationer av DUC:ar (Data Under Centraler) och diverse olika givare som tillsammans skulle ta reda på vilket värme- och ventilationsbehov som behövs vid en viss tidpunkt och styra systemen utifrån dessa.

Under projektets gång upptäcktes en rad brister och bieffekter som behövdes åtgärdas. Dessa brister var både sådana som berodde på projektet och sådana som inte hade upptäckts av Norrporten tidigare, till exempel vinande oljud, dålig verkningsgrad på värmeåtervinningen, dåliga lukter och höga lufthastigheter.

Resultat av detta projekt blev överförväntan då den uppskattade besparingen var lite mindre än 60 kWh/m2 medan den verkliga besparingen blev strax över 100 kWh/m2. Finansiellt så blev besparingen det första året nästan 75 % större än väntat, från den uppskattade summan på ca 160 000 kronor till det verkliga på ca 280 000 kronor.

Abstract [en]

This report deals with an energy efficiency project of a cinema in Umeå by controlling the indoor climate depending on the situation and by that way reduce energy consumption for heating and ventilation systems, yet managing to maintain a good indoor environment for occupants and that existing rules and laws are not broken. This energy efficiency was done by Schneider Electronic on one of Norrporten’s properties.

Studies of various laws and sets of rules, including the “Boverkets Byggregler” (BBR) and “Socialstyrelsens allmänna råd”, was done to find out how to control the heating and ventilation systems so that the indoor climate can still keep the quality required.

To know how to control the indoor climate in the theater information was needed about how the heating and ventilation systems were designed. This was investigated by means of field visits, interviews and literature studies. It appeared to be a system where the supply air was heated or cooled by a heating or cooling coil before it was sent out to the premises where the energy to the heat came from the district heating while the coolness was driven by electricity. Some radiators were in the hallways and beneath the windows in the foyer and in the theaters there were air heaters that could be used if necessary.

The energy efficiency project was that the heating and ventilation systems would not work as hard, but most important they would be running fewer hours during the day and night. This would be solved by installation of DUCs (Data under centrals) and various different sensors, which together would determine which heating and ventilation requirements needed at a particular time and control the systems based on them.

During the project a number of shortcomings and side effects were revealed and needed to be addressed. These shortcomings were both those that were due to the project and those that had not been discovered by Norrporten earlier, such as whishing noise, poor efficiency of heat recovery, bad odors and high air velocities.

The results of this project was beyond the expectations when the estimated savings were a little less than 60 kWh/m2 while the actual savings was just over 100 kWh/m2. The money that was saved the first year were nearly 75% larger than expected from the estimated figure of about 160 000 SEK to the real saving of about 280 000 SEK.

Place, publisher, year, edition, pages
2012. , 49 p.
Series
B12
National Category
Civil Engineering Building Technologies
Identifiers
URN: urn:nbn:se:umu:diva-61268OAI: oai:DiVA.org:umu-61268DiVA: diva2:565419
External cooperation
Schneider Electronics
Educational program
Bachelor of Science Programme in Civil Engineering
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-11-07 Created: 2012-11-07 Last updated: 2012-11-07Bibliographically approved

Open Access in DiVA

No full text

By organisation
Department of Applied Physics and Electronics
Civil EngineeringBuilding Technologies

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 169 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf