umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Energianalys av bergvärmeanläggning: Vid Akademiska Hus Norr AB
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2012 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Energy analysis of geothermal heating system : At Akademiska Hus Norr AB (English)
Abstract [sv]

Arbetet bestod i att utföra en energianalys av en bergvärmeanläggning åt uppdragsgivaren Akademiska Hus Norr AB vid Umeå universitets campus. Det var känt att värmepumpen var av för stor effekt för de två borrhål den var inkopplad emot, dock var det oklart hur mycket för stor och hur mycket energi som borrhålen överbelastades med. Metoden som användes vid energianalysen var prof. Bo Nordells ”handdimensionering” av bergvärme samt NIBEs dimensioneringskrav på köldbärartemperaturer. Bergvärmeanläggningen består av 2 borrhål på 100 respektive 120 m som belastas av en 10 kW värmepump. Vid dagens driftning av anläggningen skulle temperaturen på köldbäraren in till värmepumpen gå ned under -8°C vilket värmepumpen inte klarar. Resultatet blev att vid kontinuerlig värmeåterföring till borrhålen behövdes 2,5 kW värmeeffekt för att säkra en långsiktig drift. Tillsattes energin sommartid, vilket skulle kunna vara t.ex. solpaneler måste 22 kW tillsättas under perioden maj-september för att klara NIBEs dimensioneringskrav. Borrades ett nytt borrhål skulle detta behöva ha djupet 145 m för att klara kraven. Dock finns stor risk att laminär strömning uppstår under uppvärmningssäsong vilket gör att rekommendationen blir att vid åtgärd se resultaten som något av ett minimum och ta till en säkerhetsmarginal.

Abstract [en]

This thesis aim was to perform an energy analysis of a geothermal heating system for the client, Akademiska Hus Norr AB, located at Umeå University campus. It was already known that the installed power of the heat pump was too large for the two boreholes. It was however unclear as to how much the two boreholes where overloaded. The methods used in the energy analysis were ProfessorBo Nordell´s “hand-sizing-method” of geothermal heating and NIBE´s dimensioning requirements for brine temperatures. The geothermal heating system consists of two boreholes with a total depth of 100 and 120 meters and a 10 kW heat pump. Should today’s extraction continue, the brine would get colder than -8°C, which the heat pump can´t handle. The result showed that if heat was added continuously throughout the year 2,5 kW would suffice for long-term operation. If heat was added between May-September, 22 kW would be necessary to meet NIBEs´s dimensioning requirements. Should a new borehole be drilled, it would have to be at least 145 m to meet the requirements. However, there is a great risk that laminar flow occurs in the winter which leads to the recommendation to consider the results as a minimum action and take precautions in forms of a safety margin.

Place, publisher, year, edition, pages
2012. , 31 p.
Keyword [sv]
bergvärme, bergvärmeanläggning, energi, energianalys, borrhål, köldbärare
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:umu:diva-63675OAI: oai:DiVA.org:umu-63675DiVA: diva2:582177
External cooperation
Akademiska Hus, Norr AB
Subject / course
Energiteknik
Educational program
Bachelor of Science Programme in Energy Engineering
Uppsok
Technology
Supervisors
Examiners
Available from: 2013-01-08 Created: 2013-01-03 Last updated: 2013-01-08Bibliographically approved

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Näslund, Daniel
By organisation
Department of Applied Physics and Electronics
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 166 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf