umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A new method of using gas exchange measurements for the noninvasive determination of cardiac output: clinical experiences in adults following cardiac surgery
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Anaesthesiology.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Anaesthesiology.ORCID iD: 0000-0002-5325-2688
Show others and affiliations
1995 (English)In: Acta Anaesthesiol Scand, Vol. 39, no 6, 727-32 p.Article in journal (Refereed) Published
Abstract [en]

New mathematical algorithms have been applied to a computer controlled closed breathing circuit system for non-invasive measurement of cardiac output (COniv). This system has been described in an animal study. Forty patients were studied 5 and 18 hours after cardiac surgery using the thermodilution technique as the reference (COtd). The variables entered into the algorithms for COniv were oxygen uptake, carbon dioxide elimination, end-tidal carbon dioxide partial pressure, tidal volume and arterial oxygen saturation. Mixed venous carbon dioxide partial pressure was obtained from an automatically implemented short rebreathing manoeuvre. Pulmonary perfusion was calculated by a modified Fick equation for carbon dioxide and the shunt flow added to obtain COniv. During mechanical ventilation, there was a good agreement between COtd and COniv (r = 0.8). The bias was -0.14 l/min and the precision was 0.77 l/min. The reproducibility of COniv was 0.03 l/min and for COtd -0.03 l/min with a standard deviation of the difference being 0.35 l/min for COniv and 0.31 l/min for COtd. In awake, but sedated extubated patients, the method proved unsatisfactory on account for uneven tidal volumes and difficulties with leakage around the mouth piece. We conclude that this new technique provides reliable and reproducible measures of cardiac output in sedated, ventilated patients.

Place, publisher, year, edition, pages
1995. Vol. 39, no 6, 727-32 p.
Keyword [en]
Adult, Aged, Carbon Dioxide/physiology, *Cardiac Output, *Cardiac Surgical Procedures, Female, Humans, Male, Middle Aged, Oxygen/blood, *Pulmonary Gas Exchange, Reproducibility of Results, Respiration, Respiration, Artificial, Thermodilution, Ventilation-Perfusion Ratio
National Category
Anesthesiology and Intensive Care
Identifiers
URN: urn:nbn:se:umu:diva-66529ISBN: 0001-5172 (Print) OAI: oai:DiVA.org:umu-66529DiVA: diva2:607308
Note

Osterlund, B Gedeon, A Krill, P Johansson, G Reiz, S Research Support, Non-U.S. Gov't Denmark Acta anaesthesiologica Scandinavica Acta Anaesthesiol Scand. 1995 Aug;39(6):727-32.

Available from: 2013-02-22 Created: 2013-02-22 Last updated: 2015-09-15

Open Access in DiVA

No full text

Other links

http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=7484024

Authority records BETA

Österlund, BarbroJohansson, Göran

Search in DiVA

By author/editor
Österlund, BarbroJohansson, Göran
By organisation
Anaesthesiology
Anesthesiology and Intensive Care

Search outside of DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 170 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf