The Easy-X magnetic stoma connector system. A future concept for stomal dressing?
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
Dept of Surgical Science, Division of Surgery, Uppsala University, Uppsala, Sweden .
Dept of Surgical Science, Division of Surgery, Uppsala University, Uppsala, Sweden .
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi. CLINTEC, Division of Surgery, Karolinska Institutet, Stockholm, Sweden .
2013 (Engelska)Ingår i: International Journal of Colorectal Disease, ISSN 0179-1958, E-ISSN 1432-1262, Vol. 28, nr 3, s. 371-374Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A considerable proportion of stoma patients are disabled for various reasons and are elderly. To be able to dress their stoma themselves is of crucial importance for their integrity and social life. This study evaluates a novel stomal dressing system based on a magnetic connector-the Easy-X system. Twenty patients (8 women, mean age of 40-89 years) with a well-functioning colostomy tested the Easy-X system for 6 weeks. The system was judged by the patients using a multiple choice scale, and by the stoma nurses using a 10-grade VAS. Eighteen of 20 patients completed the trial. Ten patients rated the Easy-X as better than their ordinary system, 3 as equal to and 4 deemed it inferior. Despite this, only three were prepared to change to the Easy-X system. Eleven of 18 patients experienced discomfort with the new adhesive plate. Three patients suffered leakage less often and five patients more often than with their ordinary system. Stoma nurse ratings were available for 14 patients. Their evaluation of the magnetic connector in the Easy-X system was positive in eight cases, neutral in one case and negative in three cases. Global impression ratings were 3 positive, 3 negative and 5 neutral. The Easy-X system showed potential advantages over conventional stomal dressing systems, but the system must be improved in terms of a varied assortment of dressing products enabling individual fitting before a larger trial can be carried out on disabled patients. Furthermore, the increased use of metal has to be handled with an ecologic recycling system. A new stomal dressing system with a magnetic connector has potential advantages over conventional stomal dressings for disabled persons.

Ort, förlag, år, upplaga, sidor
Springer, 2013. Vol. 28, nr 3, s. 371-374
Nyckelord [en]
Stomal dressing, Stoma, Patient evaluation, Magnetic, Ostomy care
Nationell ämneskategori
Kirurgi Gastroenterologi
Identifikatorer
URN: urn:nbn:se:umu:diva-67960DOI: 10.1007/s00384-012-1527-2ISI: 000316021300011OAI: oai:DiVA.org:umu-67960DiVA, id: diva2:615921
Tillgänglig från: 2013-04-12 Skapad: 2013-04-09 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Strigård, KarinGunnarsson, Ulf

Sök vidare i DiVA

Av författaren/redaktören
Strigård, KarinGunnarsson, Ulf
Av organisationen
Kirurgi
I samma tidskrift
International Journal of Colorectal Disease
KirurgiGastroenterologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 149 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf