umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fully automated on-screen carotid intima-media thickness measurement: A screening tool for subclinical atherosclerosis
Umeå University, Faculty of Medicine, Department of Public Health and Clinical Medicine, Cardiology.
Umeå University, Faculty of Medicine, Department of Public Health and Clinical Medicine, Cardiology.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Public Health and Clinical Medicine, Cardiology.
Show others and affiliations
2013 (English)In: Journal of Clinical Ultrasound, ISSN 0091-2751, E-ISSN 1097-0096, Vol. 41, no 6, 333-339 p.Article in journal (Refereed) Published
Abstract [en]

Purpose Carotid intima-media thickness (CIMT) is generally considered an appropriate direct vascular method for cardiovascular risk assessment. The objective of this study was to evaluate the feasibility and reproducibility of a newly developed automated on-screen carotid ultrasound with respect to manual measurement with a conventional system. Methods We assessed CIMT in 50 consecutive patients (age 62 +/- 5 years, range 21-79 years, 36 men) twice, using a newly developed automated ultrasound (CardioHealth Station) and a conventional system with manual measurement (Acuson, Sequoia). For each patient, three frozen frames of the distal 10 mm of the right and left common carotid arteries were acquired on the two systems, by operators blinded to each other. The average of the mean value of three readings of each system was calculated. Results The intraclass correlation coefficient of the interoperator variability was 0.95 and 0.94 for the automated and manual measurements, respectively. The comparative coefficient of variation of the interoperator variability was 8.2 and 8.7% for the automated and manual measurements, respectively. There was no clinically relevant difference between measurements obtained by the two systems (intraclass correlation coefficient=0.98). The acquisition time of the automated system was significantly shorter than the conventional system (p<0.01). Conclusions Fully automated on-screen measurements of CIMT are feasible, faster, and as reproducible as conventional manual measurements and may be suitable and cost-effective for screening application in community medicine.

Place, publisher, year, edition, pages
Wiley-Blackwell, 2013. Vol. 41, no 6, 333-339 p.
Keyword [en]
ultrasound, carotid artery, intima-media thickness, atherosclerosis, screening
National Category
Cardiac and Cardiovascular Systems
Identifiers
URN: urn:nbn:se:umu:diva-78429DOI: 10.1002/jcu.22041ISI: 000320440100001OAI: oai:DiVA.org:umu-78429DiVA: diva2:637833
Available from: 2013-07-23 Created: 2013-07-22 Last updated: 2017-12-06Bibliographically approved
In thesis
1. Vascular ultrasound for the assessment of carotid atherosclerosis
Open this publication in new window or tab >>Vascular ultrasound for the assessment of carotid atherosclerosis
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Background: Atherosclerotic cardiovascular disease (CVD) is a common cause for mortality globally, and is expected to remain the single leading cause of death as the global population ages and as life expectancy increases.

Cardiovascular screening models have been developed, and continue to be developed, to identify individuals at high-risk of CVD.  This is necessary to establish prevention strategies to decrease the occurrence of an acute event or debilitating syndrome. These strategies largely take the form of lifestyle modification and pharmacological intervention. The Framingham risk score, NCEP/ATP II guidelines and SCORE risk assessment protocol are widely used screening models. Ultrasound based methods are non-invasive, affordable and have been suggested to improve assessment and definition of individual patients potential risk of CVD. Increased carotid artery intima-media thickness (cIMT) is a known and established sign of early atherosclerosis. The presence of plaque and the overall burden of atherosclerosis seems to have even greater value in predicting cerebrovascular and cardiovascular events. Ultrasound based texture characteristics of plaques such as entropy, grey scale median, discrete white area, coarseness and juxtaluminal hypoechoic black area have been proposed as useful possible predictors of plaque vulnerability. Moreover, ultrasound contrast agents have been developed to improve visualization and subsequent quantification of an atherosclerotic plaque. Considering the current available data and research, the importance of developing tools and techniques for detection and characterization of atherosclerotic changes, to indicate risk for CVD and the subsequent early intervention and prevention, appears clearly as an effort to improve public health. In this present collection of studies (4 papers) we aim to contribute to the development of clinically useful ultrasound methods and tools for the accurate assessment, understanding and management of atherosclerosis.

Methods: To validate ultrasound-based methods for assessment of early signs of atherosclerosis, measured as cIMT, a total of 144 subjects underwent bilateral carotid ultrasound. In study I, the performance of an ultrasonography software capable of fully automated on-screen cIMT measurements was tested and compared with the traditional manual measurement approach. The coefficient of variation and the intraclass correlation coefficient for both methods were compared to verify the reliability and reproducibility of results generated by the new ultrasound software. To test the accessibility and possible clinical applications of this new technology tested in study I, the new software was used by novice’s scanners in study II, and the intraobserver variability of the cIMT measurements were assessed and compared with that of an expert operator. In study III, ultrasound texture characteristics of 327 plaques including entropy, grey scale median, discrete white area, coarseness and juxtaluminal hypoechoic black area were assessed as possible predictors of future cerebrovascular events in a cohort of 133 patients with symptomatic carotid stenosis waiting for carotid surgery. The reproducibility of measuring plaque area (expressed as intraclass correlation coefficient) using conventional ultrasound and contrast enhanced ultrasound was tested in study IV in an attempt to find a simple and reproducible parameter for monitoring changes in atherosclerotic burden.

Results: The technology tested in study I was found to have good inter- and intra-system reproducibility compared with conventional methods. Moreover, it was found to produce reproducible results when used by expert and novice operators after a short period of training (study II), confirming the possibility for the employment of this technology in a large screening public health programs. Although such technology may have immediate practical application, other and more sophisticated ultrasound based plaque characteristics (such as grey scale median, entropy, coarseness, juxtaluminal hypoechoic black area) were not shown to be beneficial in predicting plaque vulnerability (study III). Contrast enhanced ultrasound technic tested in study IV did not improve quantification of atherosclerotic plaque burden. 

Conclusion: Medical ultrasound technology by using a automatically measure of carotid intima media thickness can be used with high reproducibility and also possible to be transferred to primary care by a well designed training program.  Plaque characteristic using carotid ultrasound was not found to be useful in risk stratifying symptomatic patients with severe carotid stenosis. Furthermore, contrast enhanced ultrasound technique was found to have high reproducibility in plaque area assessment but not better than conventional b-mode based method in quantifying the atherosclerotic burden. Therefore, more sophisticated ultrasound based methods for assessment plaque characteristics was not found to be beneficial in predicting plaque vulnerability.

Place, publisher, year, edition, pages
Umeå: Umeå University, 2017. 50 p.
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 1912
Keyword
Ultrasound, Plaque, IMT, Atherosclerosis, CEUS, Carotid vessels
National Category
Public Health, Global Health, Social Medicine and Epidemiology
Research subject
Medicine, cardiovascular disease
Identifiers
urn:nbn:se:umu:diva-139538 (URN)978-91-7601-748-7 (ISBN)
Public defence
2017-10-13, Sal D, 9 tr, Norrlands Universitetssjukhus, Umeå, 13:00 (English)
Opponent
Supervisors
Available from: 2017-09-22 Created: 2017-09-16 Last updated: 2017-09-21Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Vanoli, DavideLindqvist, PerWiklund, UrbanHenein, MichaelNäslund, Ulf
By organisation
CardiologyRadiation Physics
In the same journal
Journal of Clinical Ultrasound
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 111 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf