Utredning av värmesystem i Boliden AB:s anläggning vid Tara-gruvan
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2013 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Envestagation of heating-system in Boliden AB:s facility by the Tara-mine (Swedish)
Abstract [sv]

Sommaren 2009 besökte WSP en anläggning i anslutning till Taragruvan i Navan, Irland. Syftet av deras besök var att se över ventilationssystemet som var föråldrat. I och med besöket insåg besiktaren att även deras värmesystem var i behov av en uppdatering och den uppgiften resulterade till detta examensarbete.

 

Det övergripande syftet med arbetet är att undersöka hur ett nutida värmesystem kan byggas upp och förbättra inomhusklimatet jämfört med ett äldre system. Uppgiften i arbetet består av att ta fram ett förslag på utformningen av ett nytt system som tar hänsyn till effektbehov och dagens klimatkrav.

 

Utredningen hänvisar en anläggning som används till omklädningsrum för gruvarbetarna samt kontorslokaler. Där är inomhusmiljön bristande, speciellt i omklädningsrummet där temperaturen och den relativa fukthalten är över rekommenderande värden. Omklädningsrummet är därigenom största fokus i undersökningen. Dessutom värms systemet upp med stora mängder olja vilket bidrar med stora utsläpp till miljön. Att kunna mildra anläggningens påverkan bidrar till ökad motivering för en eventuell investering. Utgångspunkten för arbetet ligger i att upprätta ett systems uppbyggnad utifrån anläggningens behov. Därefter läggs stor vikt vid att finna de rätta komponenterna för att optimera det tilltänkta systemet. För att teoretiskt kunna bygga upp ett system till anläggningen arbetas ett förslag fram via ett flödesschema för att skapa en tidig överblick. Efter detta ska systemets komponenter dimensioneras efter anläggningens behov, där uppvärmningen av tappvarmvatten, ventilationssystem och radiatorsystem samt luftavfuktning i omklädningsrummet inkluderas. För att undersöka möjligheten till ett energieffektivare värmesystem kommer arbetet att inkludera en utvärdering av värmeväxlare, värmepump och luftavfuktare samt inkluderingen av de befintliga ventilations- och värmesystemen.

 

I resultaten redovisas ett effektiviserat teoretiskt system som minskar energiförbrukningen och förbättrar inomhusklimatet i anläggningen. Genom att utnyttja befintlig värmeenergi kan arbetet redovisa ekonomiska fördelarna som uppkommer genom val av en effektiv värmepump inom systemet.

Abstract [en]

In the summer of 2009, WSP visited a facility adjacent to the Tara-mine at Navan, Ireland. The purpose of their visit was to control the ventilation system which was outdated. During the visit the inspector detected that their heating system also was in need of updating and that task led to this bachelor thesis.

 

The overall aim of this work is to investigate how a modern heating system can be assembled to improve the indoor climate compared to an older system, where the primary target is to develop a proposal for the formation of a new system that meet the power requirements and today's climate demands.

 

The study refers to a facility used as a changing room for the miners and as an office premise. The analysis focuses on the changing rooms as the indoor environment is especially inadequate with temperature and relative air humidity above recommendatory values for good indoor climate. In addition, the system is heated with large amounts of oil which contribute with large contaminations to the environment. Being able to moderate the impact the facility contribute to the surroundings is an additional motive for any investment.

 

The analysis began with an examination of the system demands from the facility’s needs, followed by a search of potential components which could optimize a contemplated system. In order to be able to build this system theoretically correct the thesis established a flow chart. On the basis of the flow chart, the system components is conform adjusted to the facility’s needs, which includes the heating of domestic hot water, ventilation- and heating systems, as well an air dehumidification unit in the locker room. To examine the possibilities of improving the energy efficiency of this heating system, the project will evaluate heat exchangers, a heat pump and a dehumidifier, and a coupling to the existing ventilation and heating systems.

 

The results are presented as a theoretical system that reduces the facility’s energy consumption and improves indoor climate. By utilizing the accessible thermal energy, the project also presents the economic advantages from choosing an efficient heat pump within the system.

Place, publisher, year, edition, pages
2013. , 55 p.
Keyword [en]
Energy- effectiveness, heating system, heat recovery, heat-pump, dehumidifier, heat-exchanger
Keyword [sv]
Energieffektivisering, värmesystem, värmeåtervinning, värmepump, luftavfuktare, värmeväxlare
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:umu:diva-79326OAI: oai:DiVA.org:umu-79326DiVA: diva2:640723
External cooperation
WSP
Subject / course
Energiteknik
Educational program
Bachelor of Science Programme in Energy Engineering
Supervisors
Examiners
Available from: 2013-09-04 Created: 2013-08-14 Last updated: 2013-09-04Bibliographically approved

Open Access in DiVA

Utredning av värmesystem i Boliden AB:s anläggning vid Tara-gruvan(1581 kB)634 downloads
File information
File name FULLTEXT01.pdfFile size 1581 kBChecksum SHA-512
1103d010da275d6464284d35d14f120203c98d2f1b6fa08a55e7093e5c4358100e1a3513d0e2d0451f1a5dfe696efa9066671f3507ac0fc7b1fc7db21a8d9f21
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Andersson, Josefin
By organisation
Department of Applied Physics and Electronics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 634 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 342 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf