umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared application to trace detection of hydrogen peroxide
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik. JILA, National Institute of Standards and Technology and University of Colorado, Department of Physics, University of Colorado, USA.
JILA, National Institute of Standards and Technology and University of Colorado, Department of Physics, University of Colorado, Boulder, CO, 80309-0440, USA and Instytut Fizyki, Uniwersytet Mikołaja Kopernika, Torun, Poland.
JILA, National Institute of Standards and Technology and University of Colorado, Department of Physics, University of Colorado, Boulder, CO, 80309-0440, USA.
JILA, National Institute of Standards and Technology and University of Colorado, Department of Physics, University of Colorado, Boulder, CO, 80309-0440, USA.
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Applied physics. B, Lasers and optics (Print), ISSN 0946-2171, E-ISSN 1432-0649, Vol. 110, nr 2, s. 163-175Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high-power Yb:fiber laser, a high-finesse broadband cavity, and a fast-scanning Fourier transform spectrometer with autobalancing detection. The comb spectrum with a bandwidth of 200 nm centered around 3.76 μm is simultaneously coupled to the cavity and both degrees of freedom of the comb, i.e. the repetition rate and carrier envelope offset frequency, are locked to the cavity to ensure stable transmission. The autobalancing detection scheme reduces the intensity noise by a factor of 300, and a sensitivity of 5.4×10-9 cm-1 Hz-1/2 with a resolution of 800 MHz is achieved (corresponding to 6.9×10-11 cm-1 Hz-1/2 per spectral element for 6000 resolved elements). This yields a noise equivalent detection limit for hydrogen peroxide of 8 parts-per-billion (ppb); in the presence of 2.8 % of water the detection limit is 130 ppb. Spectra of acetylene, methane, and nitrous oxide at atmospheric pressure are also presented, and a line-shape model is developed to simulate the experimental data.

Ort, förlag, år, upplaga, sidor
Springer, 2013. Vol. 110, nr 2, s. 163-175
Nationell ämneskategori
Fysik Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:umu:diva-83247DOI: 10.1007/s00340-012-5024-7OAI: oai:DiVA.org:umu-83247DiVA, id: diva2:665873
Konferens
Field Laser Applications in Industry and Research - FLAIR 2011, Murnau
Tillgänglig från: 2013-11-21 Skapad: 2013-11-21 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

fulltext(3054 kB)214 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 3054 kBChecksumma SHA-512
6a658ef2c56275a77f8002b18abf7e2f92c8f22109ab147552f1d2bacc8fc0420caba85f9093845e09e1102dbbefbfa0a70e3bd715156e6772152ed2f2dcf48e
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Personposter BETA

Foltynowicz, Aleksandra

Sök vidare i DiVA

Av författaren/redaktören
Foltynowicz, Aleksandra
Av organisationen
Institutionen för fysik
I samma tidskrift
Applied physics. B, Lasers and optics (Print)
FysikTeknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 214 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 229 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf