umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Successful novice's training in obtaining accurate assessment of carotid IMT using an automated ultrasound system
Umeå University, Faculty of Medicine, Department of Public Health and Clinical Medicine, Cardiology. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Clinical Physiology.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Public Health and Clinical Medicine, Cardiology. Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Clinical Physiology.
Umeå University, Faculty of Medicine, Department of Public Health and Clinical Medicine, Cardiology.
Show others and affiliations
2014 (English)In: European Heart Journal Cardiovascular Imaging, ISSN 2047-2404, E-ISSN 2047-2412, Vol. 15, no 6, 637-642 p.Article in journal (Refereed) Published
Abstract [en]

Aims The aim of this study was to assess the feasibility and learning curve of training novice operators in using automated ultrasound to achieve satisfactory carotid intima-media thickness (CIMT) measurements. Methods and results Four novices underwent 4 weeks carotid ultrasound training using a newly developed automated ultrasonograph. A longitudinal B-mode image of the distal right common carotid artery (CCA) was acquired in 96 patients. The interoperator CIMT reproducibility was analysed by the coefficient of variation (CV) and intraclass correlation coefficient (ICC) for every week and compared with that from an expert operator. The weekly mean CV of the measurements on the 24 patients made by all novices was consistently reduced: 0.06, 0.05, 0.03, and 0.02, respectively. For the expert, the mean CV was 0.02, 0.02, 0.03, and 0.02, respectively. The novices' standard deviation (SD) of CVs also reduced weekly from 0.04 in the first week to 0.01 in the last week (P < 0.05). The corresponding weekly variation in the SD for the expert was 0.02 for the first week to 0.01 in the last week (P = 0.27). The agreement between measurements made by the novices was expressed by the ICC being 0.97 (P < 0.001) in the first week and increased to 0.99 (P < 0.001) in the fourth week. Conclusion CIMT assessment by novices using an automated ultrasound could be reliably achievable after a short training period. These results may have encouraging implications when designing screening programmes for primary prevention in community health service.

Place, publisher, year, edition, pages
2014. Vol. 15, no 6, 637-642 p.
Keyword [en]
Carotid artery, Intima-media thickness, Health screening, Vascular ultrasound
National Category
Cardiac and Cardiovascular Systems
Identifiers
URN: urn:nbn:se:umu:diva-91057DOI: 10.1093/ehjci/jet254ISI: 000336994300009OAI: oai:DiVA.org:umu-91057DiVA: diva2:733788
Available from: 2014-07-11 Created: 2014-07-10 Last updated: 2017-09-21Bibliographically approved
In thesis
1. Vascular ultrasound for the assessment of carotid atherosclerosis
Open this publication in new window or tab >>Vascular ultrasound for the assessment of carotid atherosclerosis
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Background: Atherosclerotic cardiovascular disease (CVD) is a common cause for mortality globally, and is expected to remain the single leading cause of death as the global population ages and as life expectancy increases.

Cardiovascular screening models have been developed, and continue to be developed, to identify individuals at high-risk of CVD.  This is necessary to establish prevention strategies to decrease the occurrence of an acute event or debilitating syndrome. These strategies largely take the form of lifestyle modification and pharmacological intervention. The Framingham risk score, NCEP/ATP II guidelines and SCORE risk assessment protocol are widely used screening models. Ultrasound based methods are non-invasive, affordable and have been suggested to improve assessment and definition of individual patients potential risk of CVD. Increased carotid artery intima-media thickness (cIMT) is a known and established sign of early atherosclerosis. The presence of plaque and the overall burden of atherosclerosis seems to have even greater value in predicting cerebrovascular and cardiovascular events. Ultrasound based texture characteristics of plaques such as entropy, grey scale median, discrete white area, coarseness and juxtaluminal hypoechoic black area have been proposed as useful possible predictors of plaque vulnerability. Moreover, ultrasound contrast agents have been developed to improve visualization and subsequent quantification of an atherosclerotic plaque. Considering the current available data and research, the importance of developing tools and techniques for detection and characterization of atherosclerotic changes, to indicate risk for CVD and the subsequent early intervention and prevention, appears clearly as an effort to improve public health. In this present collection of studies (4 papers) we aim to contribute to the development of clinically useful ultrasound methods and tools for the accurate assessment, understanding and management of atherosclerosis.

Methods: To validate ultrasound-based methods for assessment of early signs of atherosclerosis, measured as cIMT, a total of 144 subjects underwent bilateral carotid ultrasound. In study I, the performance of an ultrasonography software capable of fully automated on-screen cIMT measurements was tested and compared with the traditional manual measurement approach. The coefficient of variation and the intraclass correlation coefficient for both methods were compared to verify the reliability and reproducibility of results generated by the new ultrasound software. To test the accessibility and possible clinical applications of this new technology tested in study I, the new software was used by novice’s scanners in study II, and the intraobserver variability of the cIMT measurements were assessed and compared with that of an expert operator. In study III, ultrasound texture characteristics of 327 plaques including entropy, grey scale median, discrete white area, coarseness and juxtaluminal hypoechoic black area were assessed as possible predictors of future cerebrovascular events in a cohort of 133 patients with symptomatic carotid stenosis waiting for carotid surgery. The reproducibility of measuring plaque area (expressed as intraclass correlation coefficient) using conventional ultrasound and contrast enhanced ultrasound was tested in study IV in an attempt to find a simple and reproducible parameter for monitoring changes in atherosclerotic burden.

Results: The technology tested in study I was found to have good inter- and intra-system reproducibility compared with conventional methods. Moreover, it was found to produce reproducible results when used by expert and novice operators after a short period of training (study II), confirming the possibility for the employment of this technology in a large screening public health programs. Although such technology may have immediate practical application, other and more sophisticated ultrasound based plaque characteristics (such as grey scale median, entropy, coarseness, juxtaluminal hypoechoic black area) were not shown to be beneficial in predicting plaque vulnerability (study III). Contrast enhanced ultrasound technic tested in study IV did not improve quantification of atherosclerotic plaque burden. 

Conclusion: Medical ultrasound technology by using a automatically measure of carotid intima media thickness can be used with high reproducibility and also possible to be transferred to primary care by a well designed training program.  Plaque characteristic using carotid ultrasound was not found to be useful in risk stratifying symptomatic patients with severe carotid stenosis. Furthermore, contrast enhanced ultrasound technique was found to have high reproducibility in plaque area assessment but not better than conventional b-mode based method in quantifying the atherosclerotic burden. Therefore, more sophisticated ultrasound based methods for assessment plaque characteristics was not found to be beneficial in predicting plaque vulnerability.

Place, publisher, year, edition, pages
Umeå: Umeå University, 2017. 50 p.
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 1912
Keyword
Ultrasound, Plaque, IMT, Atherosclerosis, CEUS, Carotid vessels
National Category
Public Health, Global Health, Social Medicine and Epidemiology
Research subject
Medicine, cardiovascular disease
Identifiers
urn:nbn:se:umu:diva-139538 (URN)978-91-7601-748-7 (ISBN)
Public defence
2017-10-13, Sal D, 9 tr, Norrlands Universitetssjukhus, Umeå, 13:00 (English)
Opponent
Supervisors
Available from: 2017-09-22 Created: 2017-09-16 Last updated: 2017-09-21Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Vanoli, DavideWiklund, UrbanLindqvist, PerHenein, MichaelNäslund, Ulf

Search in DiVA

By author/editor
Vanoli, DavideWiklund, UrbanLindqvist, PerHenein, MichaelNäslund, Ulf
By organisation
CardiologyClinical PhysiologyRadiation Physics
In the same journal
European Heart Journal Cardiovascular Imaging
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 131 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf