Adjusting parameters of aortic valve stenosis severity by body size
Show others and affiliations
2014 (English)In: Heart, ISSN 1355-6037, E-ISSN 1468-201X, Vol. 100, no 13, 1024-1030 p.Article in journal (Refereed) Published
Abstract [en]

Background Adjustment of cardiac dimensions by measures of body size appears intuitively convincing and in patients with aortic stenosis, aortic valve area (AVA) is commonly adjusted by body surface area (BSA). However, there is little evidence to support such an approach. Objective To identify the adequate measure of body size for the adjustment of aortic stenosis severity. Methods Parameters of aortic stenosis severity (jet velocity, mean pressure gradient (MPG) and AVA) and measures of body size (height, weight, BSA and body mass index (BMI)) were analysed in 2843 consecutive patients with aortic stenosis (jet velocity >= 2.5 m/s) and related to outcomes in a second cohort of 1525 patients from the Simvastatin/Ezetimibe in Aortic Stenosis (SEAS) study. Results Whereas jet velocity and MPG were independent of body size, AVA was significantly correlated with height, weight, BSA and BMI (Pearson correlation coefficient (r) 0.319, 0.281, 0.317 and 0.126, respectively, all p<0.001) to the effect that larger patients presented with larger AVA (less severe stenosis). Of the anthropometric measures used for linear adjustment, BSA was most effective in eliminating the correlation between AVA and body size (r=0.007), rivalled only by allometric (non-linear) models, findings that are confirmed in 1525 prospectively followed patients from the SEAS study. Predictive accuracy for aortic valve events and cardiovascular death during 46 months of follow-up was unchanged by adjusting AVA, regardless of measure of body size (area under the receiver operating curve for AVA 0.72 (CI 0.58 to 0.87) versus, for example, AVA/BSA 0.75 (CI 0.61 to 0.88), p=0.22). Conclusions In the assessment of aortic stenosis, linear adjustment of AVA by BSA improves comparability between patients with diverging body size without, however, increasing the predictive accuracy for clinical events in a population with mild to moderate stenosis.

Place, publisher, year, edition, pages
2014. Vol. 100, no 13, 1024-1030 p.
National Category
Cardiac and Cardiovascular Systems
URN: urn:nbn:se:umu:diva-91052DOI: 10.1136/heartjnl-2013-305225ISI: 000336894800009OAI: diva2:733797
Available from: 2014-07-11 Created: 2014-07-10 Last updated: 2014-07-11Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Boman, Kurt
By organisation
In the same journal
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 55 hits
ReferencesLink to record
Permanent link

Direct link