Utveckling av sensor för mätning av hjärtaktivitet
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2014 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Development of sensor for measurement of cardiac activity (English)
Abstract [sv]

Rörelseanalys är ett nödvändigt verktyg då det gäller bedömning, uppföljning och diagnos vid alla de sjukdomar som påverkar den mänskliga rörelseapparaten. Idag finns det i Sverige ett fåtal kliniska gånglaboratorier dit patienter kan remitteras för att få en mer detaljerad och objektiv bedömning av deras rörelsemönster. Problemen med dessa gånglaboratorier är att de är förhållandevis dyra och resurskrävande.

Avdelningen för Medicinsk Teknik- FoU vid Norrlands Universitetssjukhus har därför initierat ett forskningsprojekt där AnyMo, ett mobilt system för mätningar av rörelsemönster, har utvecklats.

Målet med detta examensarbete var att vidareutveckla det befintliga systemet till att simultant kunna mäta hjärtats EKG, då det skulle göra undersökningen mer komplett.

De delar som konstruerades i projektet var en EKG-sensor och en Master Unit, som kopplades ihop med en befintlig rörelsesensor (del av AnyMo-systemet). Informationen från sensorerna lagrades lokalt i ett minneskort på systemets Master Unit.

Den färdiga produkten testades och utvärderades på en motionscykel vid olika nivåer av fysisk ansträngning och varierande rörelsefrekvens.

Abstract [en]

Motion analysis is a necessary tool when it comes to evaluation, monitoring and diagnosis of all the diseases that affect the human musculoskeletal system. There are only a few clinical walking laboratories in Sweden, where the patients can receive a more detailed and objective evaluation of their walking patterns. The problem with these laboratories is that they are relatively expensive and resource-demanding.

The department of research and development at NUS has initiated a research project where AnyMo, a mobile system for measuring of moving patterns, was produced. The aim of this thesis was to further develop the existing system to simultaneously measure the electrical activity of the heart (ECG).

The parts that were constructed during this project was an ECG sensor and a Master Unit, coupled to an existing motion sensor (part of the AnyMo system). The information that was collected from these sensors was stored locally in a memory on the system’s Master Unit.

The finished product was tested and evaluated on a stationary bike at different pace and heart rate.

Place, publisher, year, edition, pages
2014. , 39 p.
National Category
Medical Equipment Engineering
Identifiers
URN: urn:nbn:se:umu:diva-95931OAI: oai:DiVA.org:umu-95931DiVA: diva2:761823
External cooperation
Norrlands Universitetssjukhus, CMTS, MT-FoU
Subject / course
Elektronik
Educational program
Bachelor of Science Programme in Electronic and Computer Engeneering/ Medical engineering
Supervisors
Examiners
Available from: 2014-11-16 Created: 2014-11-08 Last updated: 2014-11-16Bibliographically approved

Open Access in DiVA

Utveckling av sensor för mätning av hjärtaktivitet(1594 kB)350 downloads
File information
File name FULLTEXT01.pdfFile size 1594 kBChecksum SHA-512
9f325accc13b3db9e7527ff614d9ee3602e8a2cc638299c463172395653d105294ede10b9b9a435c22671469c98f590eb30fdf27f922e371fcd9bacb2dd832b2
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Medical Equipment Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 350 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 278 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf