umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Correlation between Abdominal Rectus Diastasis Width and Abdominal Muscle Strength
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Surgery.
Stockholm, Sweden.
Stockholm, Sweden.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Surgery.
2015 (English)In: Digestive Surgery, ISSN 0253-4886, E-ISSN 1421-9883, Vol. 32, no 2, 112-116 p.Article in journal (Refereed) Published
Abstract [en]

Background: Surgery for Abdominal Rectus Diastasis (ARD) is a controversial topic and some argue that it is solely an aesthetic problem. Many symptoms in these patients are indefinite, and no objective criteria have been established, indicating which patients are likely to benefit from surgery. This study investigated the correlation between preoperative assessment and intraoperative measurement of ARD width, and objective measurements of muscle strength. Methods: 57 patients undergoing surgery for ARD underwent preoperative assessment of ARD width by clinical measurement and CT scan, and thereafter intraoperative measurement. Abdominal muscle strength was investigated using the Biodex System 4 including flexion, extension and isometric measurements. Correlations were calculated by the Spearman test. Results: Intraoperative ARD width between the umbilicus and the symphysis correlated strongly with Biodex measurements during flexion (p = 0.007, R = -0.35) and isometric work load (p = 0.01, R = -0.34). The following measurements showed no correlation: between muscle strength and BMI; muscle strength and waistline; or between muscle strength and ARD width above the umbilicus, assessed preoperatively at the outpatient clinic, by CT scan, or measured intraoperatively. Conclusion: There is a strong correlation between intraoperatively measured ARD width below the umbilicus and flexion and isometric abdominal muscle strength measured with the Biodex System 4.

Place, publisher, year, edition, pages
Karger , 2015. Vol. 32, no 2, 112-116 p.
Keyword [en]
Rectus diastasis, ARD, Biodex System 4, Muscle strength, Clinical symptoms
National Category
Surgery
Identifiers
URN: urn:nbn:se:umu:diva-103176DOI: 10.1159/000371859ISI: 000352870800006PubMedID: 25766128OAI: oai:DiVA.org:umu-103176DiVA: diva2:814524
Available from: 2015-05-27 Created: 2015-05-18 Last updated: 2017-12-04Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Gunnarsson, UlfStrigård, Karin
By organisation
Surgery
In the same journal
Digestive Surgery
Surgery

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 221 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf