umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Correlation between Abdominal Rectus Diastasis Width and Abdominal Muscle Strength
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
Stockholm, Sweden.
Stockholm, Sweden.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
2015 (Engelska)Ingår i: Digestive Surgery, ISSN 0253-4886, E-ISSN 1421-9883, Vol. 32, nr 2, s. 112-116Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Surgery for Abdominal Rectus Diastasis (ARD) is a controversial topic and some argue that it is solely an aesthetic problem. Many symptoms in these patients are indefinite, and no objective criteria have been established, indicating which patients are likely to benefit from surgery. This study investigated the correlation between preoperative assessment and intraoperative measurement of ARD width, and objective measurements of muscle strength. Methods: 57 patients undergoing surgery for ARD underwent preoperative assessment of ARD width by clinical measurement and CT scan, and thereafter intraoperative measurement. Abdominal muscle strength was investigated using the Biodex System 4 including flexion, extension and isometric measurements. Correlations were calculated by the Spearman test. Results: Intraoperative ARD width between the umbilicus and the symphysis correlated strongly with Biodex measurements during flexion (p = 0.007, R = -0.35) and isometric work load (p = 0.01, R = -0.34). The following measurements showed no correlation: between muscle strength and BMI; muscle strength and waistline; or between muscle strength and ARD width above the umbilicus, assessed preoperatively at the outpatient clinic, by CT scan, or measured intraoperatively. Conclusion: There is a strong correlation between intraoperatively measured ARD width below the umbilicus and flexion and isometric abdominal muscle strength measured with the Biodex System 4.

Ort, förlag, år, upplaga, sidor
Karger , 2015. Vol. 32, nr 2, s. 112-116
Nyckelord [en]
Rectus diastasis, ARD, Biodex System 4, Muscle strength, Clinical symptoms
Nationell ämneskategori
Kirurgi
Identifikatorer
URN: urn:nbn:se:umu:diva-103176DOI: 10.1159/000371859ISI: 000352870800006PubMedID: 25766128OAI: oai:DiVA.org:umu-103176DiVA, id: diva2:814524
Tillgänglig från: 2015-05-27 Skapad: 2015-05-18 Senast uppdaterad: 2018-06-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Gunnarsson, UlfStrigård, Karin

Sök vidare i DiVA

Av författaren/redaktören
Gunnarsson, UlfStrigård, Karin
Av organisationen
Kirurgi
I samma tidskrift
Digestive Surgery
Kirurgi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 354 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf