Dynamisk selektivitet i Kankbergsgruvan
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2015 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Adaptive selectivity in the Kankberg mine (English)
Abstract [sv]

Underjordsgruvor är i konstant utbyggnad neråt i berget på jakt efter mineraler. Detta medför andra utmaningar gällande elektrifieringen än vad som finns vid en installation ovan jord där den är mer permanent. Att bibehålla en god selektivitet i en underjordsgruva är en sådan utmaning. Kabellängder förändras och delar i anläggningen tillkommer eller tas bort.

I en del av ABB:s vision om ”Smart Mine Power” har New Boliden AB visat sitt intresse av att modernisera elektrifieringen i Kankbergsgruvan och undersöka ifall det är möjligt att införa en dynamisk selektivitet. En selektivitet som på ett lättare sätt kan hållas aktuell i den föränderliga elanläggningsmiljö som en underjordsgruva är.

Rapporten utreder elanläggningen i dagsläget i gruvan och dess förutsättningar för att kunna implementera dynamisk selektivitet. Ett enlinjeschema ritades sedan upp för hur en ”visionsgruva” skulle se ut vid implementering.

Förslagen åtgärd för Kankbergsgruvans 10 kV spänningsnivå är att använda sig av ett riktat numeriskt överströmsrelä och en brytare på båda sidor av ställverken. Båda reläskydden är uppkopplade mot ett överliggande datasystem i vilket en händelsetabell upprättas för reläernas inställningar för alla gruvans tänkbara driftfall. Vid kort- eller jordslutning eller förändring i gruvans elanläggning kan driftfall snabbt skiftas och selektiviteten fortsätter att vara aktuell.

Abstract [en]

Underground mines are in constant development, expanding deeper into to the earth in search of minerals. This creates other challenges than electrical installations above ground where they are more permanent. Maintaining a good selectivity in the electrical grid when cables and plant components are constantly added or removed is one those challenges.

As part of ABB's vision of "Smart Mine Power", New Boliden AB has shown their interest in modernizing the electrification components of Kankberg mine and to examine if it is possible, and what is needed, to introduce adaptive selectivity. A selectivity which is offering a greater ease and flexibility in the changing environment of the electrical grid in an underground mine.

This report investigates Kankberg mines current electrical system and its conditions for introducing adaptive selectivity. A new single-line diagram is drawn for how a "vision mine" would look with an adaptive selectivity made possible.

The proposed measure for the Kankberg mine 10 kV voltage level is the use of circuit breakers with connected numerical directional overcurrent relays on both sides of the electrical substation. Both of those relays are connected to an overhead computer system, in which an event table drawn up for the relay settings for all the mines operating cases. If a fault occurs or changes are made in the electrical system the operational case can quickly be changed so that selectivity continues to be up-to-date.

Place, publisher, year, edition, pages
2015. , 27 p.
Series
EL, 1520
Keyword [sv]
Dynamisk selektivitet, elkraft, gruva
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:umu:diva-104887OAI: oai:DiVA.org:umu-104887DiVA: diva2:821464
External cooperation
ABB AB
Educational program
Högskoleingenjörsprogrammet i Elkraftteknik - nätbaserat
Supervisors
Examiners
Available from: 2015-06-18 Created: 2015-06-15 Last updated: 2015-06-18Bibliographically approved

Open Access in DiVA

fulltext(1574 kB)229 downloads
File information
File name FULLTEXT01.pdfFile size 1574 kBChecksum SHA-512
5c3616c5c272d1aa23dac2f9ecda9442c2be1030d813d588986bb7c903be1a6e6e5af5c19a2b4432f54e07279d28f75924ba3a070a0abf5718ce713be34ddf67
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 229 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 208 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf