Energijämförelse av ett flerbostadshus
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2015 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Energy comparison of an apartment building (English)
Abstract [sv]

Dagens husbyggande handlar mycket om att huset ska använda så lite energi som möjligt. Vid nybyggnation eller renovering av byggnad krävs en energiberäkning.  Detta kan påverka när entreprenören garanterar en energianvändning som är svår att styra över. Den individuella brukarens beteende påverkar energianvändningen mycket.

 

Projektet syftar till att jämföra den specifika energianvändningen för energiberäkningen och energianvändning. Detta för att skapa en förståelse om hur dessa relaterar till varandra.

 

Det är svårt att göra en energiberäkning som stämmer överens med verkligheten. Det är många parametrar som måste antas. Det är vanligt med schablonvärden som avser tappvarmvatten, belysning och maskiner. Dessa tre parametrar styr brukaren över och de är svåra att uppskatta.

 

Resultatet av rapporten visar en skillnad mellan den specifika energianvändningen för beräknad och verklig användning för ett specifikt projekt. Skillnaden var 24,5 kWh/m2,år. Denna skillnad är mest beroende på användningen av tappvarmvatten. Det är brukaren som styr detta värde, det bevisar att årsschabloner inte alltid går att använda.

 

Slutsatsen av detta projekt är att det är svårt att upprätta en beräkning som stämmer överens med verkligheten. Det största problemet vid beräkningar är hur ingångsdata hanteras då det är dessa som bestämmer utgången av beräkningen. Brukaren av fastigheten styr energianvändningen, det är svårt att i beräkningen att uppskatta vilken sorts brukare som kommer använda fastigheten. 

Abstract [en]

Today's building construction is about using as little amount of energy as possible. With new buildings or renovation it is always required to create an energy calculation. This is something that is problematic. When the contractor promises an expenditure that is very difficult to control. The way an individual user behave has big impact on the use of energy.The project aims to compare the specific energy consumption of energy calculation and use of energy. This is to build an understanding of how these relate to each other.It is very difficult to make an energy calculation that is consistent with the reality. There are many parameters that need to be adopted. The most commonly used values for the hot water, lighting and appliances is based on statistics. The individual user controls these three parameters and it is hard to estimate these values when you are doing the calculationThe result of the report shows a difference between the specific energy use for the calculation and actual use. The difference is 24.5 kWh/m2,year this difference is mostly affected by the hot water use. It is the user that controls this value, this proves that the templates cannot always be used.The conclusion of this project is that it is difficult to establish a calculation that corresponds with reality. The biggest problem for calculations is how the input data is handled when it is those who determines the end of the calculation. The user of the property controls energy use, it is difficult in the calculation to estimate what kind of users who will use the property.

Place, publisher, year, edition, pages
2015.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:umu:diva-104976OAI: oai:DiVA.org:umu-104976DiVA: diva2:822306
External cooperation
Peab Sverige AB
Educational program
Bachelor of Science Programme in Civil Engineering
Supervisors
Examiners
Available from: 2015-06-16 Created: 2015-06-16 Last updated: 2015-06-16Bibliographically approved

Open Access in DiVA

fulltext(2778 kB)116 downloads
File information
File name FULLTEXT01.pdfFile size 2778 kBChecksum SHA-512
adc966d7c4d33fdfe054b197d77317252673bb07499caabe0ca7c11537467dfc1292b92259bb2f0d89a91c9f6dc5b5aac4ab71dc8433051257735379fe846847
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 116 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 149 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf