Spänningsfall i 200 V 400 Hz system
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2015 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Voltage drop in 200 V 400 Hz systems (English)
Abstract [sv]

Målet med examensarbetet har varit att ta fram teoretiskt underlag och en beräkningsmodell. Detta ska beskriva hur kabeltyp, kabellängd, kabelarea samt effektfaktor påverkar spänningsfallet över ett 400 Hz ledningssystem.

Mätningar har utförts på två olika kablar som används i det aktuella systemet. En av kablarna var symm­et­riskt uppbyggd med 7 ledare, där respektive fas bestod av två ledare förskjutna 180° från varandra runt nolledaren. För att åstadkomma 115/200V 400 Hz, användes en 90 kVA frekvensomformare. Belastningen som användes var en resistiv, induktiv samt en kapacitiv belastning. Med den resistiva belastningen justerades effekten för att ställa in den effektfaktor som önskades under mätningarna. Detta var inte möjligt med den induktiva eller den kapacitiva belastningen, då de inte kunde regleras steglöst.  

Beräkningsmodellen jämfördes sedan med mätningarna av spänningsfallet. Den visade sig ge en bra uppskattning av de uppmätta värdena för att kunna användas i Saabs fortsatta arbete.

Vidare ges förslag på hur de distorsioner som uppstår, i samband med komplexa laster, kan minskas. Detta för att klara de standardiserade mått på elkvaliteten som ställs i de gällande standarderna MIL-STD-704E och ISO 6858-1982 (E).

Beräkningsmodellen och dess beräkningar presenteras dock inte i denna rapport, då det av Saab AB är sekretessbelagda.

Abstract [en]

The goal with this bachelor thesis has been to present theoretical material and a calculation model. This is to be used to explain how cable type, cable length, cable area affects the voltage drop in a 400 Hz power system.

Measurements have been made on two different cables that are being used in the current system. One of the cables was built symmetrically built with 7-conduktors, where each phase consisted of two conductors shifted 180° from each other around the neutral conductor. To establish the system voltage 115/200 V 400 Hz, a 90 kVA frequency converter was used. The load that was used under the measurements was a resistive, inductive and a capacitive load-equipment. With the resistive load active power is adjusted to obtain the proper power factor for different measurements. This was not an option with the inductive or the capacitive load-equipment since they could not be regulated with a rheostat as the resistive load.

The calculation model was compared with the measured results of the voltage drop. It was proven that it approximated the voltage drop good enough to be used in Saabs future work.

Furthermore, suggestions are made of how to minimize the distortions that are developed by complex loads, to clear the demands on power quality presented by the standards MIL-STD-704E and ISO 6858-1982 (E).

Place, publisher, year, edition, pages
2015.
Series
EL, 1527
Keyword [en]
400 Hz, Voltage drop, Saab
Keyword [sv]
400 Hz, Spänningsfall, Saab
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:umu:diva-105189OAI: oai:DiVA.org:umu-105189DiVA: diva2:823938
External cooperation
Saab AB
Subject / course
Elektronik
Educational program
Högskoleingenjörsprogrammet i Elkraftteknik - nätbaserat
Supervisors
Examiners
Available from: 2015-06-22 Created: 2015-06-18 Last updated: 2015-08-10Bibliographically approved

Open Access in DiVA

fulltext(2295 kB)105 downloads
File information
File name FULLTEXT02.pdfFile size 2295 kBChecksum SHA-512
e118085bc45494ba3ddd6dbfe07af1470c2eb5b5b1b9664dbc593a3d174658f53d5cb793f94e3d773ce23f62d55cdb4c914ac47cd8c3310d1719e05eebee459d
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 117 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 260 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf