Development of a Quality Assurance Strategy for Magnetic Resonance Imaging in Radiotherapy
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik. Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Centrum för medicinsk teknik och fysik (CMTF).
2015 (Engelska)Självständigt arbete på avancerad nivå (masterexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

Radiotherapy is a common treatment option for malignant tumors. The use of magnetic resonance imaging in radiotherapy is increasing world-wide and sets additional requirements on the image quality compared to diagnostics applications. Thereby, the overall goal of the present project was to develop and implement a structured image quality assurance approach for MRI in radiotherapy. Specific aspects studied was the image quality, spatial accuracy and spin-lattice relaxation time quantification. Measurements using three different phantoms were performed at the positron emission tomography magnetic resonance (PET/MR) scanner at Norrlands Univeristy Hosptial, Umeå. The image quality was evaluated using the American College of Radiology (ACR) phantom and its accompanying tests. ACR phantom measurements were performed once or twice daily throughout the project. The results from the ACR tests were implemented in an automatic analysis program and displayed on a website, accessible from the hospital network. The image quality was found to be constant over time and within acceptance values. Furthermore, the spatial distortion was quantified using a large field of view (FOV) phantom and a spatial analysis program supplied with the phantom. A method to study the reproducibility of the distortion was developed and the distortion in the PET/MR scanner was mapped in different images planes. The image distortion was shown to be reproducible and less than 1 mm inside a volume of 20x20x20 cm3 around the magnetic isocenter, which corresponds to a FOV used in target delineations images. However, outside this volume larger distortions than 2 mm was observed. In order to evaluate the quantification of the spin-lattice relaxation time two methods were evaluated, variable flip angle (VFA) and two point inversion recovery spin echo (IRSE) using the Test object 5 (TO5) phantom. Large variations in the quantification was observed using the VFA method compared to the two point IRSE method when performing phantom measurements. Unfortunately, the two point IRSE method was not adequate when used in head exams in the clinical practice.

Ort, förlag, år, upplaga, sidor
2015. , s. 53
Nyckelord [en]
MRI, magnetic resonance imaging, PET/MRI, quality assurance, strategy, radiotherapy
Nationell ämneskategori
Annan medicinteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-105979OAI: oai:DiVA.org:umu-105979DiVA, id: diva2:839470
Externt samarbete
NUS
Ämne / kurs
Examensarbete i teknisk fysik
Utbildningsprogram
Civilingenjörsprogrammet i Teknisk fysik
Handledare
Examinatorer
Tillgänglig från: 2015-08-10 Skapad: 2015-07-02 Senast uppdaterad: 2015-08-10Bibliografiskt granskad

Open Access i DiVA

QA for MRI in RT applications(27998 kB)2710 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 27998 kBChecksumma SHA-512
894a66f85bb370cea817169638ee3849d24399417509272868f3285a96d84254129ec80f6acd5bcd21c4865d35222659a083ee21242edcfdb78389d82105e5d6
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Sandgren, Kristina
Av organisationen
Institutionen för fysikRadiofysik
Annan medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 2710 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 4791 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf