2015 (English)In: Operative Neurosurgery, ISSN 2332-4252, Vol. 11, no 3, 412-419 p.Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: Magnetic resonance imaging (MRI)-verified deep brain stimulation relies on the correct interpretation of stereotactic imaging documenting lead location in relation to visible anatomic target. However, it has been suggested that local signal distortion from the lead itself renders its depiction on MRI unreliable. OBJECTIVE: To compare lead location on stereotactic MRI with subsequent location of its brain track after removal. METHODS: Patients underwent deep brain stimulation with the use of MRI-guided and MRI-verified Leksell frame approach. Infection or suboptimal efficacy required lead removal and subsequent reimplantation by using the same technique. Postimplantation stereotactic MR images were analyzed. Lateral (x) and anteroposterior (y) distances from midcommissural point to center of the lead hypointensity were recorded at the anterior commissure-posterior commissure plane (pallidal electrode) or z = 24 (subthalamic electrode). Stereotactic MRI before the second procedure, x and y distances from the center of the visible lead track hypointensity to midcommissural point were independently recorded. Vectorial distance from center of the lead hypointensity to the center of its track was calculated. RESULTS: Sixteen electrode tracks were studied in 10 patients. Mean differences between lead artifact location and lead track location were: x coordinate 0.4 mm +/- 0.2; y coordinate 0.6 mm +/- 0.3. Mean vectorial distance was 0.7 mm +/- 0.2. CONCLUSION: Stereotactic distance between lead location and subsequent brain track location on MRI was small. The mean discrepancy was approximately half the deep brain stimulation lead width. This suggests that lead hypointensity seen on postimplantation MRI is indeed an accurate representation of its real location within deep brain structures.

Place, publisher, year, edition, pages
Lippincott Williams & Wilkins, 2015. Vol. 11, no 3, 412-419 p.
Keyword [en]
Deep brain stimulation, Magnetic resonance imaging-verified surgery, Stereotactic accuracy
National Category
Neurology Surgery
Identifiers
URN: urn:nbn:se:umu:diva-112017DOI: 10.1227/NEU.0000000000000848ISI: 000364216700021OAI: oai:DiVA.org:umu-112017DiVA: diva2:875049
Available from: 2015-11-30 Created: 2015-11-30 Last updated: 2015-11-30Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text
By organisation
Clinical Neuroscience
NeurologySurgery

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 13 hits
ReferencesLink to record
Permanent link

Direct link