umu.sePublications
Change search
ReferencesLink to record
Permanent link

Direct link
Age-dependency of ocular parameters: a cross sectional study of young and elderly healthy subjects
Umeå University, Faculty of Medicine, Department of Clinical Sciences, Ophthalmology.
Umeå University, Faculty of Medicine, Department of Radiation Sciences. Umeå University, Faculty of Science and Technology, Centre for Biomedical Engineering and Physics (CMTF).
Umeå University, Faculty of Science and Technology, Centre for Biomedical Engineering and Physics (CMTF). Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Science and Technology, Centre for Biomedical Engineering and Physics (CMTF). Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Show others and affiliations
2015 (English)In: Graefe's Archives for Clinical and Experimental Ophthalmology, ISSN 0721-832X, E-ISSN 1435-702X, Vol. 253, no 11, 1979-1983 p.Article in journal (Refereed) Published
Abstract [en]

To investigate the effect of aging on ocular parameters, including intraocular pressure (IOP), measured with different tonometry methods in healthy young (HY) and healthy elderly (HE) subjects and to study the effect of corneal parameters on tonometry methods. In this prospective, cross-sectional study, fifty eyes of 50 HY subjects (28 females, 22-31 years of age) and 43 eyes of 43 HE subjects (22 females, 64-79) were included. IOP was measured with four tonometry methods in a standardized order: ocular response analyser (ORA), dynamic contour tonometry (DCT), applanation resonance tonometry (ART) and Goldmann applanation tonometry (GAT). Other measurements included axial length (AL), central corneal thickness (CCT), corneal curvature (CC), anterior chamber volume (ACV), corneal hysteresis (CH) and corneal resistance factor (CRF). The mean IOP (HY/HE; mmHg +/- standard deviation (SD)) was 12.2 +/- 2.2/14.1 +/- 3.5 with GAT. IOP was significantly higher (difference +/- standard error) in HE compared to HY measured with an ORA (+3.1 mmHg +/- 0.6), GAT (+1.9 +/- 0.6) and DCT (+1.6 +/- 0.6). No significant difference was found in IOP measured with ART. CH and ACV were significantly lower in HE compared to HY. There was no difference between the groups in CCT, CC, AL or CRF. No tonometry method was dependant on CCT or CC. IOP measured with an ORA and via DCT and GAT was higher in HE compared to HY Swedish subjects, while IOP measured with ART did not differ between the groups. In these homogeneous groups, tonometry methods were independent of CCT and CC.

Place, publisher, year, edition, pages
Springer, 2015. Vol. 253, no 11, 1979-1983 p.
Keyword [en]
Intraocular pressure, Age dependency, Central corneal thickness, Corneal curvature, Ocular response analyser, Dynamic contour tonometry, Applanation resonance tonometry
National Category
Ophthalmology
Identifiers
URN: urn:nbn:se:umu:diva-111465DOI: 10.1007/s00417-015-3129-5ISI: 000363057900020PubMedID: 26267751OAI: oai:DiVA.org:umu-111465DiVA: diva2:875935
Available from: 2015-12-02 Created: 2015-11-13 Last updated: 2015-12-02Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Johannesson, GautiHallberg, PerAmbarki, KhalidEklund, AndersLinden, Christina
By organisation
OphthalmologyDepartment of Radiation SciencesCentre for Biomedical Engineering and Physics (CMTF)Radiation Physics
In the same journal
Graefe's Archives for Clinical and Experimental Ophthalmology
Ophthalmology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 122 hits
ReferencesLink to record
Permanent link

Direct link